Руководство пользователя OLYMPUS BX61. Основные функции, характеристики и условия эксплуатации изложены на 40 страницах документа в pdf формате.
Доступно к просмотру 38 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
INSTRUCTIONS BX61 MOTORIZED SYSTEM MICROSCOPES This instruction manual is for the Olympus Motorized System Microscopes Models BX61 and BX62. To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of this microscope, we recommend that you study this manual thoroughly before operating the micro- scope. Retain this instruction manual in an easily accessible place near the work desk for future reference. A X 7 6 1 1
BX61 CONTENTS Correct assembly and adjustments are indispensable to allow the microscope manifest its full performance. If you are going to assemble the microscope by yourself, please read chapter 7, “ASSEMBLY” (pages. 29 to 32). IMPORTANT — Be sure to read this section for safe use of the equipment. — 1-3 1 NOMENCLATURE 4-5 2 TRANSMITTED LIGHT BRIGHTFIELD OBSERVATION PROCEDURE 6-7 3 USING THE CONTROLS 8-21 3-1 Base ................................................................................................................................................................................................................. 8-10 1 Voltage Indication 2 Transmitted/Reflected Light Switch 3 Light Preset Switch 4 Using the Filters 3-2 Focusing Block............................................................................................................................................................................... 11-12 1 Replacing the Focus Adjustment Knob 2 F/C button 3 Stage UP/DOWN Buttons 4 Stage Escape Button 3-3 Stage ............................................................................................................................................................................................................ 13-15 1 Placing the Specimen 2 Adjusting the X/Y-Axis Knob Tension 3 Rotating the Stage 4 Adjusting the Stage Height 3-4 Observation Tube....................................................................................................................................................................... 16-18 1 Adjusting the Interpupillar Distance 2 Adjusting the Diopter 3 Using the Eye Shades 4 Using the Eyepiece Micrometer Disk 5 Selecting the Light Path of the Trinocular Tube 6 Adjusting the Tilt 3-5 Condenser .......................................................................................................................................................................................... 19-20 1 Centering the Condenser 2 Compatibility of Objectives and Condensers 3-6 Immersion Objectives................................................................................................................................................................... 21 3-7 Objectives with Correction Collar ............................................................................................................................... 21 4 TROUBLESHOOTING GUIDE 22-24 5 SPECIFICATIONS 25-26 6 OPTICAL CHARACTERISTICS <> 27-28 7 ASSEMBLY — See this section for the replacement of the light bulb. — 29-32 PROPER SELECTION OF THE POWER SUPPLY CORD................................................................... 33-34
This device complies with the requirements of directive 98/79/EC concerning in vitro diag- nostic medical devices. CE marking means the conformity to the directive. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.