На сайте 124131 инструкция общим размером 502.48 Гб , которые состоят из 6274836 страниц
Руководство пользователя HOTPOINT-ARISTON FTCF 87B 6H. Основные функции, характеристики и условия эксплуатации изложены на 64 страницах документа в pdf формате.
Доступно к просмотру 64 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Instruction booklet TUMBLE DRYER Contents GB PT RU Installation, 2 NL English, 1 Portugues, 17 Русский, 33 Warnings, 4 Care and maintenance, 6 KZ Control Panel, 8 ?аза?ша, 49 The Display, 9 Start and Programmes, 10 Laundry, 14 Troubleshooting, 15 Service, 16 FTCF 87B www.hotpoint.eu ! This symbol reminds you to read this instruction manual. ! Keep this instruction booklet on hand in order to refer to it when necessary. Take it with you when you move, and, should you sell this appliance or pass it on to another party, make sure that this booklet is supplied along with the dryer so that the new owner may be infor- med about warnings and suggestions on how the dryer works. ! Read these instructions carefully; the following pages contain impor- tant information on installation and suggestions on how the appliance works 1
Installation Where to install the tumble dryer GB • Install the dryer far 2 2 from gas ranges, stoves, radiators or hobs, as 10 mm 1 1 flames may damage it. If the dryer is installed H<1m below a worktop, 15 mm 15 mm ensure there are 10 mm between the upper panel of the Picture A Picture B dryer and any objects above it, and 15 mm between the sides of the machine and the walls or furniture units Electrical connections adjacent to it. This ensures adequate air Before plugging the appliance into the socket, circulation.The appliance must be installed check the following: with the rear surface placed against a wall. • Make sure your hands are dry. • The socket must have an earth connection. Ventilation • The socket must be able to withstand • The room must be adequately ventilated while the dryer the machine’s maximum power output as is running. Make sure that the dryer is installed in a room indicated on the rating plate. that is not damp and has with adequate air circulation. The • The power supply voltage must fall within flow of air around the dryer is essential to allow water to condense during drying; the dryer will not function properly if the values indicated on the data plate. it is placed in an enclosed space or inside a cabinet. • The socket must be compatible with the ! Some condensation may form if the dryer is used in a small dryer’s plug. Should this not be the case, or cold room. replace the plug or the socket. !We do not recommend that the dryer is ! DO NOT use extension cords. installed in a cupboard but the dryer must never ! The dryer must not be installed outdoors, be installed behind a lockable door, a sliding even if the space is sheltered. It can be very door or a door with a hinge on the opposite dangerous if exposed to rain or storms. side to that of the dryer door. ! Once installed, the dryer’s electrical wire and plug must be within reach. Water drain ! The power cord must not be bent or If your dryer is installed next to a drain the water can be squashed. plumbed into this drain. This does away with the need to ! The power must be regularly checked. If the empty the water container. If the dryer is stacked onto or installed next to a washing machine it can share the same supply cord is damaged, it must be replaced drain. The height of the drain must be less than 3’ (1 m) from by the manufacturer, its service agent or the bottom of the dryer. simi-larly qualified persons in order to avoid a Remove existing hose from position shown in picture A and fit hazard. (see Assistance). New or longer electric a suitable length of hose and connect as shown in picture B. cords are supplied by authorised dealers at a supplementary cost. ! Make sure that the hose is not squashed or kinked ! The manufacturer denies any when the dryer is in its final location. responsibility should any of these rules not be followed. ! If in doubt about any of the above consult a qualified electrician Preliminary information Once the tumble dryer is installed, clean the inside of the drum before operating it and remove any dirt accumulated during transportation. 2
Maximum load: 8 kg GB Product Data - Regulation 392/2012. Brand HOTPOINT/ARISTON Model FTCF 87B 6H (EU) Rated capacity of cotton laundry for the "standard cotton 8.0 programme" at full load - kg This household tumble drier is a Condenser Energy efficiency class on a scale from A+++ (low consumption) B to D (high consumption) The weighted Annual Energy Consumption (AEc)* kWh 1) 560.0 This household tumble drier is a Automatic Energy consumption full load; Edry - kWh 2) 4.74 Energy consumption partial load; Edry? - kWh 2) 2.56 Power consumption: off-mode (Po) - Watts 0.14 Power consumption: left-on mode (Pl) - Watts 2.77 Duration of the 'left-on mode' for power management system - minutes 30 Prog. Time - weighted (Tt) full & partial load - minutes 3) 110 Full load (Tdry) - minutes 145 Partial load (Tdry?) - minutes 83 Condensation efficiency class on a scale from G (least efficient) to B A (most efficient) Average condensation efficiency - % weighted (Ct) full & partial load 3) 81 full load (Cdry) 81 partial load (Cdry?) 81 Airborne acoustical noise emissions - dB(A) re 1 pW 69 1) "Standard cotton” at full and partial load is the standard programme to which the information in the label and the fiche relates. The standard cotton program is suitable to dry at cupboard level (0%) cotton laundry and is the most efficient programme in terms of energy consumption. Partial load is half the rated load. 2) based on 160 drying cycles of the standard cotton programme at full and partial load, and the consumption of the low-power modes. Actual energy consumption will depend on how the appliance is used. 3) Weighted average of 3 cycles at full load and 4 cycles at half load. Regulation 932/2012. Energy consumption in kWh, for program “Synthetics” full load 1.38 Programme time in minute, for program “Synthetics” full load 65 Partial load for program “Synthetics” N/A 3