На сайте 124204 инструкции общим размером 502.84 Гб , которые состоят из 6278868 страниц
Руководство пользователя INDESIT MVI5G11(X). Основные функции, характеристики и условия эксплуатации изложены на 40 страницах документа в pdf формате.
Доступно к просмотру 38 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Operating Instructions COOKER GB Contents GB RU KZ Installation, 2-5 English, 1 РУССКИЙ, 13 ?аза?ша?аза?ша ,27 Positioning and levelling Electrical connections Gas connection Adapting to different types of gas Technical data Table of burner and nozzle specifications Description of the appliance, 6 Overall view Control panel I5GG0G RU I5GG10G RU Start-up and use, 7-9 Using the hob MVI5G11 /RU Using the oven MVI5G1 /RU I5GG0.1 RU Oven cooking advice table Precautions and tips, 10 General safety Disposal Respecting and conserving the environment Maintenance and care, 11 Switching the appliance off Cleaning the appliance Gas tap maintenance Replacing the oven light bulb Assistance
Installation ! Before operating your new appliance please read Disposing of combustion fumes this instruction booklet carefully. It contains GB important information concerning the safe installation The disposal of combustion fumes should be and operation of the appliance. guaranteed using a hood connected to a safe and ! Please keep these operating instructions for future efficient natural suction chimney, or using an electric reference. Make sure that the instructions are kept fan that begins to operate automatically every time with the appliance if it is sold, given away or moved. the appliance is switched on (see figure). ! The appliance must be installed by a qualified professional according to the instructions provided. ! Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply. ! We recommend cleaning the oven before using it for the first time, following the instructions provided in the "Care and maintenance" section. Room ventilation Fumes channelled Fumes channelled through straight outside a chimney or branched The appliance may only be installed in permanently- flue system reserved for ventilated rooms, according to current national cooking appliances) legislation. The room in which the appliance is ! The liquefied petroleum gases are heavier than air installed must be ventilated adequately so as to and collect by the floor, therefore all rooms provide as much air as is needed by the normal gas containing LPG cylinders must have openings combustion process (the flow of air must not be leading outside so that any leaked gas can escape 3 lower than 2 m /h per kW of installed power). easily. The air inlets, protected by grilles, should have a LPG cylinders, therefore, whether partially or duct with an inner cross section of at least 100 cm 2 completely full, must not be installed or stored in and should be positioned so that they are not liable rooms or storage areas that are below ground level to even partial obstruction (see figure A). (cellars, etc.). Only the These inlets should be enlarged by 100% - with a cylinder being used should be stored in the room; minimum of 200 cm - whenever the surface of the this should also be kept well away from sources 2 hob is not equipped with a flame failure safety of heat (ovens, chimneys, stoves) that may cause device. When the flow of air is provided in an the temperature of the cylinder to rise above 50°C. indirect manner from adjacent rooms (see figure B), provided that these are not communal parts of a Positioning and levelling building, areas with increased fire hazards or bedrooms, the inlets should be fitted with a ! It is possible to install the appliance alongside ventilation duct leading outside as described above. cupboards whose height does not exceed that of the Adjacent room Room requiring hob surface. ventilation A B ! Make sure that the wall in contact with the back of the appliance is made from a non-flammable, heat- resistant material (T 90°C). To install the appliance correctly: A • Place it in the kitchen, dining room or the bed-sit (not in the bathroom). Ventilation opening for Increase in the gap between • If the top of the hob is higher than the cupboards, comburent air the door and the flooring the appliance must be installed at least 200 mm away from them. ! After prolonged use of the appliance, it is • If the cooker is installed underneath a wall cabinet, advisable to open a window or increase the speed of there must be a minimum distance of 420 mm any fans used. between this cabinet and the top of the hob. This distance should be increased to 700 mm if the wall cabinets are flammable (see figure). 2
! Once the appliance has been installed, the power • Do not position supply cable and the electrical socket must be GB HOOD blinds behind the easily accessible. cooker or less than 200 ! The cable must not be bent or compressed. Min. 600mm. mm away from its ! The cable must be checked regularly and replaced 420mm. 420mm. min. 650 mm. with hood min. 700 mm. without hood sides. by authorised technicians only. • Any hoods must be Min. Min. installed according to ! The manufacturer declines any liability should the instructions listed in these safety measures not be observed. the relevant operating Gas connection manual. Connection to the gas network or to the gas cylinder may be carried out using a flexible rubber or steel Levelling hose, in accordance with current national legislation If it is necessary to level the and after making sure that the appliance is suited to appliance, screw the the type of gas with which it will be supplied (see the adjustable feet into the places rating sticker on the cover: if this is not the case see provided on each corner of the below). When using liquid gas from a cylinder, install a base of the cooker (see pressure regulator which complies with current national figure). regulations. To make connection easier, the gas supply may be turned sideways*: reverse the position of the hose holder with that of the cap and replace the The legs* fit into the slots on gasket that is supplied with the appliance. the underside of the base of the cooker. ! Check that the pressure of the gas supply is consistent with the values indicated in the Table of burner and nozzle specifications (see below). This will ensure the safe operation and durability of your appliance while maintaining efficient energy consumption. Electrical connection Gas connection using a flexible rubber hose Install a standardised plug corresponding to the load indicated on the appliance data plate (see Make sure that the hose complies with current Technical data table). national legislation. The internal diameter of the hose The appliance must be directly connected to the mains must measure: 8 mm for liquid gas supply; 13 mm using an omnipolar circuit-breaker with a minimum for methane gas supply. contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be Once the connection has been performed, make suitable for the charge indicated and must comply with sure that the hose: NFC 15-100 regulations (the earthing wire must not be • Does not come into contact with any parts that interrupted by the circuit-breaker). The supply cable reach temperatures of over 50°C. must be positioned so that it does not come into • Is not subject to any pulling or twisting forces and contact with temperatures higher than 50°C at any point. that it is not kinked or bent. • Does not come into contact with blades, sharp Before connecting the appliance to the power corners or moving parts and that it is not supply, make sure that: compressed. • The appliance is earthed and the plug is compliant • Is easy to inspect along its whole length so that with the law. its condition may be checked. • The socket can withstand the maximum power of • Is shorter than 1500 mm. the appliance, which is indicated by the data plate. • Fits firmly into place at both ends, where it will be • The voltage is in the range between the values fixed using clamps that comply with current indicated on the data plate. regulations. • The socket is compatible with the plug of the appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets. * Only available in certain models 3