Operating Instructions OVEN Contents GB Installation, 2-3 GB RS Positioning Electrical connections English,1 Русский, 10 Data plate Description of the appliance, 4 Overall view Control panel Start-up and use, 5 Starting the oven Cooking modes, 6-7 Cooking modes Practical cooking advice Cooking advice table 7OFIM 20 K.A Precautions and tips, 8 7OFIM 20 K.A IX General safety 7OFIMS 20 K.A Disposal 7OFIMS 20K.A IX Respecting and conserving the environment Maintenance and care, 9 Switching the appliance off Cleaning the appliance Cleaning the oven door Replacing the light bulb Assistance
Installation ! Before placing your new appliance into operation Ventilation GB please read these operating instructions carefully. They contain important information for safe use, for To ensure good ventilation, the back panel of the installation and for care of the appliance. cabinet must be removed. It is advisable to install the oven so that it rests on two strips of wood, or on a ! Please keep these operating instructions for future completely flat surface with an opening of at least 45 x reference. Pass them on to possible new owners of 560 mm (see diagrams). the appliance. Positioning 45 mm. 560 mm. ! Keep packaging material out of the reach of children. It can become a choking or suffocation hazard. (see Precautions and tips). ! The appliance must be installed by a qualified person in compliance with the instructions provided. Incorrect installation may cause harm to persons, Centring and fastening animals or may damage property. Secure the appliance to the cabinet by opening the Fitting the appliance oven door and putting 4 screws into the 4 holes of the outer frame. Use the appropriate cabinet to ensure that the appliance functions properly. • The panels adjacent to the oven must be made of heat-resistant material. • Cabinets with a veneer exterior must be assembled with glues which can withstand temperatures of up to 100°C. • to install the oven under the counter (see diagram) and in a kitchen unit, the cabinet must have the following dimensions: ! All parts which ensure the safe operation of the appliance must not be removable without the aid of a tool. 547 mm. min. 23 mm. 45 mm. 595 mm. 567 mm. 560 mm. 575-585 mm. 5 mm. 545 mm. 595 mm. 24 mm. ! The appliance must not come into contact with electrical parts once it has been installed. The consumption indications on the data plate have been calculated for this type of installation. 2
Electrical connections • The socket can withstand the maximum power of GB the appliance, which is indicated on the data plate ! Ovens equipped with a three-pole power supply (see below). cable are designed to operate with alternating current at the voltage and frequency indicated on the data • The voltage must be in the range between the plate located on the appliance (see below). values indicated on the data plate (see below). Fitting the power supply cable • The socket is compatible with the plug of the appliance. If the socket is incompatible with the 1. Open the terminal plug, ask an authorised technician to replace it. Do board by inserting a not use extension cords or multiple sockets. screwdriver into the side tabs of the cover. ! Once the appliance has been installed, the power Use the screwdriver as supply cable and the electrical socket must be easily a lever by pushing it accessible. down to open the cover (see diagram). ! The cable must not be bent or compressed. 2. Loosen the cable ! The cable must be checked regularly and replaced clamp screw and by authorised technicians only (see Assistance). remove it, using a screwdriver as a lever ! The manufacturer declines any liability should (see figure). these safety measures not be observed. 3. Remove the wire contact screws L-N- , then fasten the wires under the screw heads, respecting the colour code: Blue (N), Brown (L) and Yellow-Green Verde ( ). DATA PLATE width cm 43.5 Connecting the supply cable to the mains Dimensions height cm 32 depth cm 43,5 Install a standardised plug corresponding to the load Volume lt. 60 indicated on the data plate (see side). voltage: 220-240V ~ 50/60 Hz (see The appliance must be directly connected to the Electrical data plate) connections mains using an omnipolar circuit-breaker with a maximum power absorbed 2250W minimum contact opening of 3 mm installed between Directive 2002/40/EC on the label the appliance and the mains, suitable for the load of electric ovens. indicated and complying with current electrical Standard EN 50304 regulations (the earthing wire must not be interrupted ENERGY LABEL Energy consumption Class by the circuit-breaker). The supply cable must not certification Natural convection heating mode: Traditional come into contact with surfaces with temperatures mode. higher than 50°C. This appliance conforms to the ! The installer must ensure that the correct electrical following European Economic Community directives: connection has been made and that it is compliant - 2006/95/EEC of 12/12/06 (Low with safety regulations. Voltage) and subsequent amendments; Before connecting to the power supply, make sure - 2004/108/EEC of 15/12/04 that: (Electromagnetic Compatibility) and subsequent amendments; • The appliance is earthed and the plug is compliant - 93/68/EEC of 22/07/93 and with the law. subsequent amendments. - 2002/96/EC and subsequent amendments. 3