На сайте 124133 инструкции общим размером 502.49 Гб , которые состоят из 6275104 страниц
Руководство пользователя HOTPOINT-ARISTON PC 640 T (AN) R. Основные функции, характеристики и условия эксплуатации изложены на 20 страницах документа в pdf формате.
Доступно к просмотру 20 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Operating Instructions HOB Contents GB Installation, 2-5 GB RS Positioning Electrical connection English, 1 ???????? ?? Gas connection Data plate Burner and nozzle specifications Description of the appliance, 6 Overall view Start-up and use, 7 Practical advice on using the burners Precautions and tips, 8 General safety Disposal 7HPC 640 T GH /HA Maintenance and care, 9 7HPC 640 T R/HA Switching the appliance off 7HPC 640 T X /HA Cleaning the appliance 7HPC 640 T R/HA Gas tap maintenance 7HPC 640 /HA 7HPC 640 X /HA Troubleshooting, 10 7HPC 631 X /HA 7HPC 640 GH /HA 7HPC 640 N /HA 7HPC 640 N GH /HA 7HPC 640 N X /HA GPN 64 TA CI RFH GPN 64 TO CI RFH GPN 64 NI RFH GPN 64 NCI RFH GPN 64 NW RFH GPN 64 CI RFH 1
Installation GB ! Before operating your new appliance please read LPG cylinders, whether partially or completely full, this instruction booklet carefully. It contains important must not be installed or stored in rooms or storage information for safe use, installation and care of the areas that are below ground level (cellars, etc.). It appliance. is advisable to keep only the cylinder being used in ! Please keep these operating instructions for future the room, positioned so that it is not subject to heat reference. Pass them on to possible new owners of the produced by external sources (ovens, fireplaces, appliance. stoves, etc. ) which could raise the temperature of the cylinder above 50°C. Positioning ! Keep packaging material out of the reach of children. Fitting the appliance It can become a choking or suffocation hazard (see Gas and mixed hobs are manufactured with type X Precautions and tips). degree protection against overheating. The following ! The appliance must be installed by a qualified precautions must be taken when installing the hob: professional according to the instructions provided. • Kitchen cabinets adjacent to the appliance and taller Incorrect installation may cause harm to people and than the top of the hob must be at least 600 mm animals or may damage property. from the edge of the hob. ! This unit may be installed and used only in • Hoods must be installed according to their relative permanently ventilated rooms in accordance with installation instruction manuals and at a minimum British Standard Codes Of Practice: B.S. 6172 / B.S. distance of 650 mm from the hob. 5440, Par. 2 and B.S. 6891 Current Editions. The • Place the wall cabinets adjacent to the hood at following requirements must be observed: a minimum height of 420 mm from the hob (see • The room must be equipped with an air extraction figure). system that expels any combustion fumes. This may consist of a hood or an electric fan that automatically If the hob is installed beneath a starts each time the appliance is switched on. wall cabinet, the latter must be situated at a minimum of 700 600mm min. 650mm min. 420mm min. mm above the hob (see figure). In a chimney stack or branched flue. Directly to • The installation cavity should have the dimensions (exclusively for cooking appliances) the Outside indicated in the figure. Fastening hooks are provided, allowing you to fasten • The room must also allow proper air circulation, as the hob to tops that are between 20 and 40 mm air is needed for combustion to occur normally. The thick. To ensure the hob is securely fastened to the flow of air must not be less than 2 m /h per kW of top, we recommend you use all the hooks provided. 3 installed power. The air circulation system may 555 mm take air directly from the outside by means of a pipe with an 55 mm inner cross section of at least 100 cm ; the opening must not 475 mm 2 A be vulnerable to any type of Examples of ventilation holes blockages. for comburant air. The system can also provide Hook fastening diagram Adjacent Room to be Room Vented the air needed for combustion indirectly, i.e. from adjacent rooms fitted with air circulation tubes as described above. However, these rooms must not be communal rooms, bedrooms Enlarging the ventilation slot or rooms that may present a fire between window and floor. hazard. Hooking position Hooking position for top H=20 mm for top H=30 mm • Liquid petroleum gas sinks to the floor as it is Front heavier than air. Therefore, rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. As a result 2
indicated on the data plate. GB The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). The supply cable must not come into contact with surfaces with temperatures higher than 50°C. Hooking position Back ! The installer must ensure that the correct electrical for top H=40 mm connection has been made and that it is compliant with safety regulations. ! Use the hooks contained in the “accessory pack” Before connecting to the power supply, make sure that: • Where the hob is not installed over a built-in oven, a • The appliance is earthed and the plug is compliant wooden panel must be installed as insulation. This with the law. must be placed at a minimum distance of 20 mm • The socket can withstand the maximum power of the from the lower part of the hob. appliance, which is indicated on the data plate. Ventilation • The voltage is in the range between the values To ensure adequate ventilation, the back panel of indicated on the data plate. the cabinet must be removed. It is advisable to install • The socket is compatible with the plug of the the oven so that it rests on two strips of wood, or on a appliance. If the socket is incompatible with the completely flat surface with an opening of at least 45 x plug, ask an authorised technician to replace it. Do 560 mm (see diagrams). not use extension cords or multiple sockets. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. When installing ! The cable must not be bent or compressed. 560 mm. 45 mm. the ! The cable must be checked regularly and replaced by authorised technicians only (see Assistance). cooktop above ! The manufacturer declines any liability should these a built- safety measures not be observed. in oven without Gas connection forced The appliance should be connected to the main ventilation, ensure that there are air inlets and outlets for ventilating gas supply or to a gas cylinder in compliance with current national regulations. Before carrying out the the interior of the cabinet adequately. connection, make sure the cooker is compatible with the gas supply you wish to use. If this is not the case, follow the instructions indicated in the paragraph “Adapting to different types of gas.” When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations. ! Check that the pressure of the gas supply is consistent with the values indicated in Table 1 (“Burner and nozzle specifications”). This will ensure the safe operation and longevity of your appliance while maintaining efficient energy consumption. Electrical connection Connection with a rigid pipe (copper or steel) Hobs equipped with a three-pole power supply cable ! Connection to the gas system must be carried out in are designed to operate with alternating current at the such a way as not to place any strain of any kind on voltage and frequency indicated on the data plate (this the appliance. is located on the lower part of the appliance). The earth There is an adjustable L-shaped pipe fitting on the wire in the cable has a green and yellow cover. If the appliance supply ramp and this is fitted with a seal appliance is to be installed above a built-in electric in order to prevent leaks. The seal must always be oven, the electrical connection of the hob and the replaced after rotating the pipe fitting (seal provided oven must be carried out separately, both for electrical with appliance). The gas supply pipe fitting is a safety purposes and to make extracting the oven threaded 1/2 gas cylindrical male attachment. easier. Connecting the supply cable to the mains Install a standardised plug corresponding to the load 3