На сайте 124133 инструкции общим размером 502.49 Гб , которые состоят из 6275104 страниц
Руководство пользователя HOTPOINT-ARISTON CG 65SG1 X. Основные функции, характеристики и условия эксплуатации изложены на 48 страницах документа в pdf формате.
Доступно к просмотру 48 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Operating Instructions COOKER GB Contents GB RS UA Installation, 2-6 English,1 РУССКИЙ, 13 Украінська, 26 Positioning and levelling Electrical connection Gas connection RO Adapting to different types of gas Technical data Romanian, 37 Table of burner and nozzle specifications Description of the appliance, 7 Overall view Control panel Start-up and use, 8-10 Using the hob Using the oven CG65SG5 UA/HA Oven cooking advice table CG65SG1 UA/HA Electronic timer, 9 Setting the clock and timer Precautions and tips, 11 General safety Disposal Respecting and conserving the environment Care and maintenance, 12 Switching the appliance off Cleaning the appliance Replacing the oven light bulb Gas tap maintenance Assistance
Installation ! Before operating your new appliance please read Disposing of combustion fumes GB this instruction booklet carefully. It contains important information concerning the safe installation and The disposal of combustion fumes should be operation of the appliance. guaranteed using a hood connected to a safe and efficient natural suction chimney, or using an electric ! Please keep these operating instructions for future fan that begins to operate automatically every time the reference. Make sure that the instructions are kept with appliance is switched on (see figure). the appliance if it is sold, given away or moved. ! The appliance must be installed by a qualified professional according to the instructions provided. ! Any necessary adjustment or maintenance must be performed after the cooker has been disconnected from the electricity supply. Room ventilation Fumes channelled Fumes channelled through straight outside a chimney or a branched The appliance may only be installed in permanently- flue system (reserved for ventilated rooms, according to current national cooking appliances) legislation. The room in which the appliance is ! The liquefied petroleum gases are heavier than air installed must be ventilated adequately so as to and collect by the floor, therefore all rooms containing provide as much air as is needed by the normal gas LPG cylinders must have openings leading outside so combustion process (the flow of air must not be lower than 2 m /h per kW of installed power). that any leaked gas can escape easily. 3 The air inlets, protected by grilles, should have a duct LPG cylinders, therefore, whether partially or with an inner cross section of at least 100 cm and completely full, must not be installed or stored in 2 should be positioned so that they are not liable to rooms or storage areas that are below ground level even partial obstruction (see figure A). (cellars, etc.). Only the cylinder being used should be These inlets should be enlarged by 100% - with a stored in the room; this should also be kept well away from sources of heat (ovens, chimneys, stoves) that minimum of 200 cm - whenever the surface of the hob may cause the temperature of the cylinder to rise 2 is not equipped with a flame failure safety device. When the flow of air is provided in an indirect manner above 50°C. from adjacent rooms (see figure B), provided that these are not communal parts of a building, areas with Positioning and levelling increased fire hazards or bedrooms, the inlets should ! It is possible to install the appliance alongside be fitted with a ventilation duct leading outside as cupboards whose height does not exceed that of the described above. hob surface. Adjacent room Room requiring ! Make sure that the wall in contact with the back of ventilation A B the appliance is made from a non-flammable, heat- resistant material (T 90°C). To install the appliance correctly: • Place it in the kitchen, dining room or the bed-sit (not in the bathroom). • If the top of the hob is higher than the cupboards, A the appliance must be installed at least 600 mm Ventilation opening Increase in the gap away from them. for comburent air between the door and • If the cooker is installed underneath a wall cabinet, the flooring there must be a minimum distance of 420 mm between this cabinet and the top of the hob. ! After prolonged use of the appliance, it is advisable This distance should be increased to 700 mm if the to open a window or increase the speed of any fans wall cabinets are flammable (see figure). used. 2
• The voltage is in the range between the values indicated on the data plate. GB HOOD • The socket is compatible with the plug of the Min. 600mm. appliance. If the socket is incompatible with the 420mm. 420mm. min. 650 mm. with hood min. 700 mm. without hood plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets. Min. Min. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. • Do not position blinds behind the cooker or less ! The cable must not be bent or compressed. than 200 mm away from its sides. • Any hoods must be installed according to the ! The cable must be checked regularly and replaced instructions listed in the relevant operating manual. by authorised technicians only. Levelling ! The manufacturer declines any liability should these safety measures not be observed. If it is necessary to level the appliance, screw the adjustable Gas connection feet into the places provided on Connection to the gas network or to the gas cylinder each corner of the base of the may be carried out using a flexible rubber or steel hose, cooker (see figure). in accordance with current national legislation and after making sure that the appliance is suited to the type of gas with which it will be supplied (see the rating sticker The legs* fit into the slots on on the cover: if this is not the case see below). When the underside of the base of using liquid gas from a cylinder, install a pressure the cooker. regulator which complies with current national regulations. To make connection easier, the gas supply may be turned sideways*: reverse the position of the hose holder with that of the cap and replace the gasket that is supplied with the appliance. Electrical connection ! Check that the pressure of the gas supply is consistent with the values indicated in the Table of Install a standardised plug corresponding to the load burner and nozzle specifications (see below). This will indicated on the appliance data plate (see Technical ensure the safe operation and durability of your data table). appliance while maintaining efficient energy The appliance must be directly connected to the mains consumption. using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance Gas connection using a flexible rubber hose and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current Make sure that the hose complies with current national national legislation (the earthing wire must not be legislation. The internal diameter of the hose must interrupted by the circuit-breaker). The supply cable must measure: 8 mm for liquid gas supply; 13 mm for be positioned so that it does not come into contact with methane gas supply. temperatures higher than 50°C at any point. Once the connection has been performed, make sure that the hose: Before connecting the appliance to the power supply, make sure that: • Does not come into contact with any parts that • The appliance is earthed and the plug is compliant with reach temperatures of over 50°C. the law. • Is not subject to any pulling or twisting forces and • The socket can withstand the maximum power of the that it is not kinked or bent. appliance, which is indicated by the data plate. • Does not come into contact with blades, sharp corners or moving parts and that it is not * Only available in certain models compressed. 3