На сайте 124146 инструкций общим размером 502.54 Гб , которые состоят из 6275689 страниц
Руководство пользователя HOTPOINT-ARISTON C 3V M5 (W). Основные функции, характеристики и условия эксплуатации изложены на 24 страницах документа в pdf формате.
Доступно к просмотру 23 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Operating Instructions COOKER AND OVEN Contents GB Installation, 2-3 GB RS Positioning and levelling Electrical connections English, 1 ?ONNEEE,12 Technical data Description of the appliance, 4 Overall view Control panel Start-up and use, 5-8 Starting the oven Cooking modes Electronic timer Oven cooking advice table Using the glass ceramic hob, 9 Switching the cooking zones on and off Cooking zones C3VM5R Precautions and tips, 10 General safety Disposal Respecting and conserving the environment Care and maintenance, 11 Switching the appliance off Cleaning the oven Replacing the oven light bulb Cleaning the glass ceramic hob Assistance
Installation ! Before operating your new appliance please read The legs* provided with the GB this instruction booklet carefully. It contains appliance fit into the slots on important information concerning the safe installation the underside of the base of and operation of the appliance. the cooker. ! Please keep these operating instructions for future reference. Make sure that the instructions are kept with the appliance if it is sold, given away or moved. Electrical connections ! The appliance must be installed by a qualified professional according to the instructions provided. Fitting the power supply cable ! Any necessary adjustment or maintenance must be The cable should be suited to the type of electrical performed after the appliance has been connection used, according to the following disconnected from the electricity supply. connection diagram: Positioning and levelling 400 3N 1 2 3 4 5 H05RR-F 5x2.5 CEI-UNEL 35363 R S T N ! It is possible to install the appliance alongside 400V 2N 1 2 3 4 5 cupboards whose height does not exceed that of the H05RR-F 4x2.5 CEI-UNEL 35363 R S N hob surface. 230V 1N 1 2 3 4 5 ! Make sure that the wall in contact with the back of H07RN-F 3x4 CEI-UNEL 35364 N R the appliance is made from a non-flammable, heat- resistant material (T 90°C). To install the power supply cable correctly: To install the appliance correctly: ? Place it in the kitchen, the dining room or the bed- 1. Loosen the screw V sit (not in the bathroom). in the terminal board ? If the top of the hob is higher than the cupboards, and pull the cover to the appliance must be installed at least 200 mm open it (see figure). V away from them. ? If the cooker is HOOD installed underneath a wall cabinet, there must be a Min. 600mm. minimum distance of 420 420mm. 420mm. min. 650 mm. with hood min. 700 mm. without hood mm between this cabinet Min. Min. and the top of the hob. 2. Position the connection This distance should be increased to 700 mm if support A (see figure) 3 2 the wall cabinets are according to the 1 flammable (see figure). connection diagram shown above. The terminal board ? Do not position blinds behind the cooker or less is designed for single- than 200 mm away from its sides. phase 230 V connection: B ? Any hoods must be installed according to the terminals 1, 2 and 3 are A instructions listed in the relevant operating manual. N connected to each other; Levelling jumper 4-5 is located in the If it is necessary to level the lower area of the terminal board. appliance, screw the 3. Position wires N and 6 according to the diagram adjustable feet* into the (see figure) and perform the connection by places provided on each tightening the terminal board screws as much as corner of the base of the possible. cooker (see figure). 4. Position the remaining wires on terminals 1-2-3 and tighten the screws. 2
TECHNICAL DATA 5. Fix the power supply cable in place by fastening GB the cable clamp screw. Oven dimensions 6. Close the terminal board cover by tightening the 34x44x39 cm (HxWxD) screws V. Volume 58 l Useful width 42 cm measurements Connecting the supply cable to the mains depth 44 cm relating to the oven height 17 cm compartment Install a standardised plug corresponding to the Power supply voltage and see data plate load indicated on the data plate located on the frequency appliance. Ceramic hob The appliance must be directly connected to the Front Left 1200 W mains using an omnipolar circuit-breaker with a Back Left 1800 W minimum contact opening of 3 mm installed between Back Right 1200 W Front Right 1800 W the appliance and the mains. The circuit-breaker Max. ceramic hob must be suitable for the charge indicated and must consumption 6000 W comply with current electrical regulations (the earthing wire must not be interrupted by the circuit- Directive 2002/40/EC on the label of electric ovens. Standard EN 50304 breaker). The supply cable must be positioned so Energy consumption for Natural that it does not come into contact with temperatures convection ? heating mode: a Static; higher than 50°C at any point. ENERGY LABEL Declared energy consumption for Before connecting the appliance to the power Forced convection Class ? heating mode: b Fan-assisted. supply, make sure that: ? The appliance is earthed and the plug is compliant with the law. ? The socket can withstand the maximum power of EC Directives: 73/23/EEC dated 19/02/73 (Low Voltage) and subsequent the appliance, which is indicated by the data amendments ? plate. 89/336/EEC dated 03/05/89 ? The voltage is in the range between the values (Electromagnetic Compatibility) and indicated on the data plate. subsequent amendments ? 93/68/EEC dated 22/07/93 and ? The socket is compatible with the plug of the subsequent amendments ? appliance. If the socket is incompatible with the 2002/96/EC. plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. ! The cable must not be bent or compressed. ! The cable must be checked regularly and replaced by authorised technicians only. ! The manufacturer declines any liability should these safety measures not be observed. Only available in certain models. * 3