Operating Instructions HOB Contents GB Installation, 2-5 GB RS Positioning Electrical connection English, 1 ???????,11 Gas connection Data plate Burner and nozzle specifications Description of the appliance, 6 Overall view Start-up and use, 7 Practical advice on using the burners Practical advice on using the electric hotplates Precautions and tips, 8 General safety Disposal CISPF 640 E IX/HA 7HPF 640 S RU/HA Maintenance and care, 9 7HPF 640 E IX RU/HA Switching the appliance off 7HPF 640 E RU/HA Cleaning the appliance 7HPF 640 ES IX RU/HA Gas tap maintenance 7HPF 640 ES RU/HA Troubleshooting, 10
Installation ! Before operating your new appliance please read this also be equipped with vents to allow gas to escape in the GB instruction booklet carefully. It contains important information event of a leak. As a result LPG cylinders, whether for safe use, installation and care of the appliance. partially or completely full, must not be installed or stored ! Please keep these operating instructions for future in rooms or storage areas that are below ground level reference. Pass them on to possible new owners of the (cellars, etc.). It is advisable to keep only the cylinder appliance. being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, Positioning fireplaces, stoves, etc. ) which could raise the ! Keep packaging material out of the reach of children. It temperature of the cylinder above 50°C. can become a choking or suffocation hazard (see Precautions and tips). Fitting the appliance ! The appliance must be installed by a qualified professional Gas and mixed hobs are manufactured with type X degree protection against overheating. The following according to the instructions provided. Incorrect installation precautions must be taken when installing the hob: may cause harm to people and animals or may damage property. • Kitchen cabinets adjacent to the appliance and taller ! This unit may be installed and used only in permanently than the top of the hob must be at least 600 mm from the edge of the hob. ventilated rooms in accordance with British Standard Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891 • Hoods must be installed according to their relative Current Editions. The following requirements must be installation instruction manuals and at a minimum observed: distance of 650 mm from the hob. • The room must be equipped with an air extraction system • Place the wall cabinets adjacent to the hood at a that expels any combustion fumes. This may consist of a minimum height of 420 mm from the hob (see figure). hood or an electric fan that automatically starts each time the appliance is switched on. If the hob is installed beneath a wall cabinet, the latter must be situated at a minimum of 700 mm 700mm min. 600mm min. above the hob (see figure). 600mm min. In a chimney stack or branched flue. Directly to (exclusively for cooking appliances) the Outside • The installation cavity should have the dimensions indicated in the figure. • The room must also allow proper air circulation, as air is needed for combustion to occur normally. The flow of air Fastening hooks are provided, allowing you to fasten the must not be less than 2 m /h per kW of installed power. hob to tops that are between 20 and 40 mm thick. To 3 The air circulation system may ensure the hob is securely fastened to the top, we take air directly from the outside recommend you use all the hooks provided. by means of a pipe with an inner 55 mm cross section of at least 100 cm ; 2 A the opening must not be vulnerable to any type of 475 mm Examples of ventilation holes blockages. for comburant air. The system can also provide the Adjacent Room to be 555 mm air needed for combustion Hook fastening diagram Room Vented indirectly, i.e. from adjacent rooms fitted with air circulation tubes as described above. However, these rooms must not be communal Enlarging the ventilation slot rooms, bedrooms or rooms that between window and floor. may present a fire hazard. Hooking position Hooking position • Liquid petroleum gas sinks to the floor as it is heavier for top H=20 mm for top H=30 mm than air. Therefore, rooms containing LPG cylinders must 2
Front Connecting the supply cable to the mains Install a standardised plug corresponding to the load GB indicated on the data plate. The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). The Hooking position Back supply cable must not come into contact with surfaces with for top H=40 mm temperatures higher than 50°C. ! Use the hooks contained in the “accessory pack” ! The installer must ensure that the correct electrical • Where the hob is not installed over a built-in oven, a connection has been made and that it is compliant with wooden panel must be installed as insulation. This must safety regulations. be placed at a minimum distance of 20 mm from the Before connecting to the power supply, make sure that: lower part of the hob. • The appliance is earthed and the plug is compliant with Ventilation the law. To ensure adequate ventilation, the back panel of the • The socket can withstand the maximum power of the cabinet must be removed. It is advisable to install the oven appliance, which is indicated on the data plate. so that it rests on two strips of wood, or on a completely flat • The voltage is in the range between the values indicated surface with an opening of at least 45 x 560 mm (see on the data plate. diagrams). • The socket is compatible with the plug of the appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension 560 mm. 45 mm. cords or multiple sockets. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. ! The cable must not be bent or compressed. ! The cable must be checked regularly and replaced by Where a hob is installed above an oven without a forced authorised technicians only (see Assistance). ventilation cooling system, adequate ventilation must be ! The manufacturer declines any liability should these safety provided inside the cabinet by means of air holes through measures not be observed. which air can pass (see figure). Gas connection The appliance should be connected to the main gas supply or to a gas cylinder in compliance with current national regulations. Before carrying out the connection, make sure the cooker is compatible with the gas supply you wish to use. If this is not the case, follow the instructions indicated in the paragraph “Adapting to different types of gas.” When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations. Electrical connection ! Check that the pressure of the gas supply is consistent Hobs equipped with a three-pole power supply cable are with the values indicated in Table 1 (“Burner and nozzle designed to operate with alternating current at the voltage specifications”). This will ensure the safe operation and and frequency indicated on the data plate (this is located on longevity of your appliance while maintaining efficient the lower part of the appliance). The earth wire in the cable energy consumption. has a green and yellow cover. If the appliance is to be Connection with a rigid pipe (copper or steel) installed above a built-in electric oven, the electrical ! Connection to the gas system must be carried out in connection of the hob and the oven must be carried out such a way as not to place any strain of any kind on the separately, both for electrical safety purposes and to make appliance. extracting the oven easier. 3