На сайте 124184 инструкции общим размером 502.81 Гб , которые состоят из 6278551 страницы
Руководство пользователя HOTPOINT-ARISTON 7HPK 755 D GH X /HA. Основные функции, характеристики и условия эксплуатации изложены на 32 страницах документа в pdf формате.
Доступно к просмотру 30 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Operating Instructions HOB Contents GB Installation, 2-4 GB RS KZ Positioning Electrical connection English, 1 Русский, 10 Gas connection Burner and nozzle specifications Description of the appliance, 5 Overall view Start-up and use, 6 Practical advice on using the burners Data plate Precautions and tips, 7 General safety Disposal 7HPK 644 D GH X /HA Maintenance and care, 8 7HPKQ 644 D GH /HA Switching the appliance off 7HPK 755 D GH X/HA Cleaning the appliance 7HPKQ 755 D GH /HA Gas tap maintenance Troubleshooting, 9 1
Installation ! Before operating your new appliance please read this Fitting the appliance GB instruction booklet carefully. It contains important information Gas and mixed hobs are manufactured with type X for safe use, installation and care of the appliance. degree protection against overheating. The following ! Please keep these operating instructions for future precautions must be taken when installing the hob: reference. Pass them on to possible new owners of the • Kitchen cabinets adjacent to the appliance and taller appliance. than the top of the hob must be at least 600 mm from Positioning the edge of the hob. ! Keep packaging material out of the reach of children. It • Hoods must be installed according to their relative can become a choking or suffocation hazard (see installation instruction manuals and at a minimum Precautions and tips). distance of 650 mm from the hob. ! The appliance must be installed by a qualified professional • Place the wall cabinets adjacent to the hood at a according to the instructions provided. Incorrect installation minimum height of 420 mm from the hob (see figure). may cause harm to people and animals or may damage property. If the hob is installed beneath a wall cabinet, the latter must be ! This unit may be installed and used only in permanently situated at a minimum of 700 mm ventilated rooms in accordance with British Standard Codes 600mm min. Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891 700mm min. 600mm min. above the hob (see figure). Current Editions. The following requirements must be observed: • The room must be equipped with an air extraction system that expels any combustion fumes. This may consist of a • The installation cavity should have the dimensions hood or an electric fan that automatically starts each time indicated in the figure. Fastening hooks are provided, the appliance is switched on. allowing you to fasten the hob to tops that are between 20 and 40 mm thick. To ensure the hob is securely fastened to the top, we recommend you use all the hooks provided. 55 mm In a chimney stack or branched flue. Directly to (exclusively for cooking appliances) the Outside 475 mm • The room must also allow proper air circulation, as air is needed for combustion to occur normally. The flow of air 3 must not be less than 2 m /h per kW of installed power. 555 mm The air circulation system may • Before fastening the cooktop in place, position the seal take air directly from the outside (supplied) along the perimeter of the countertop, as by means of a pipe with an inner shown in the figure. cross section of at least 100 cm ; 2 A the opening must not be Examples of ventilation holes vulnerable to any type of for comburant air. blockages. Adjacent Room to be The system can also provide the Room Vented air needed for combustion indirectly, i.e. from adjacent rooms Hook fastening diagram fitted with air circulation tubes as described above. However, these rooms must not be communal Enlarging the ventilation slot rooms, bedrooms or rooms that between window and floor. may present a fire hazard. Hooking position Hooking position for top H=20 mm for top H=30 mm 2
Front and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). GB The supply cable must not come into contact with surfaces with temperatures higher than 50°C. ! The installer must ensure that the correct electrical connection has been made and that it is compliant with safety regulations. Before connecting to the power supply, make sure that: • The appliance is earthed and the plug is compliant with the law. • The socket can withstand the maximum power of the Hooking position Back appliance, which is indicated on the data plate. for top H=40 mm • The voltage is in the range between the values indicated ! Use the hooks contained in the “accessory pack” on the data plate. • Where the hob is not installed over a built-in oven, a • The socket is compatible with the plug of the appliance. If wooden panel must be installed as insulation. This the socket is incompatible with the plug, ask an must be placed at a minimum distance of 20 mm from authorised technician to replace it. Do not use extension the lower part of the hob. cords or multiple sockets. Ventilation ! Once the appliance has been installed, the power supply To ensure adequate ventilation, the back panel of the cable and the electrical socket must be easily accessible. cabinet must be removed. It is advisable to install the ! The cable must not be bent or compressed. oven so that it rests on two strips of wood, or on a ! The cable must be checked regularly and replaced by completely flat surface with an opening of at least 45 x authorised technicians only (see Assistance). 560 mm (see diagrams). ! The manufacturer declines any liability should these safety measures not be observed. 560 mm. 45 mm. Gas connection The appliance should be connected to the main gas supply in compliance with current national regulations. Before carrying out the connection, make sure the cooker is compatible with the gas supply you wish to use. ! The hob can only be installed above built-in ovens with a ! Check that the pressure of the gas supply is consistent cooling ventilation system. with the values indicated in Table 1 (“Burner and nozzle specifications”). This will ensure the safe operation and longevity of your appliance while maintaining efficient Electrical connection energy consumption. Hobs equipped with a three-pole power supply cable are Connection with a rigid pipe (copper or steel) designed to operate with alternating current at the voltage and frequency indicated on the data plate (this is located ! Connection to the gas system must be carried out in on the lower part of the appliance). The earth wire in the such a way as not to place any strain of any kind on the cable has a green and yellow cover. If the appliance is to appliance. be installed above a built-in electric oven, the electrical There is an adjustable L-shaped pipe fitting on the connection of the hob and the oven must be carried out appliance supply ramp and this is fitted with a seal in separately, both for electrical safety purposes and to order to prevent leaks. The seal must always be replaced make extracting the oven easier. after rotating the pipe fitting (seal provided with appliance). The gas supply pipe fitting is a threaded 1/2 Connecting the supply cable to the mains gas cylindrical male attachment. Install a standardised plug corresponding to the load indicated on the data plate. The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated 3