На сайте 124193 инструкции общим размером 502.83 Гб , которые состоят из 6278723 страниц
Руководство пользователя HOTPOINT-ARISTON 7HPC 631 X/HA. Основные функции, характеристики и условия эксплуатации изложены на 44 страницах документа в pdf формате.
Доступно к просмотру 42 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Operating Instructions HOB Contents GB Installation, 2-5 GB RS ?? Positioning Electrical connection English, 1 ????????? ?? ???????????? ?? Gas connection Data plate Burner and nozzle specifications KZ Description of the appliance, 6 ????? Overall view Start-up and use, 7 Practical advice on using the burners Precautions and tips, 8 General safety Disposal 7HPC 640 /HA Maintenance and care, 9 7HPC 640 X/HA Switching the appliance off 7HPC 640 GH/HA Cleaning the appliance 7HPC 631 /HA Gas tap maintenance 7HPC 631 X/HA Troubleshooting, 10 7HPC 640N /HA 7HPC 640N GH/HA 7HPC 640N X /HA PC 640N /HA PC 640N X/HA 7HPC 640 T GH /HA 7HPC 640 T R /HA 7HPC 640 T X /HA GPN 64 NW RFH GPN 64 NCI RFH GPN 64 NI RFH GPN 64 A CI RFH GPN 64 O CI RFH GPN 64 TA CI RFH GPN 64 TO CI RFH 1
Installation ! Before operating your new appliance please read this also be equipped with vents to allow gas to escape in the GB instruction booklet carefully. It contains important information event of a leak. As a result LPG cylinders, whether for safe use, installation and care of the appliance. partially or completely full, must not be installed or stored ! Please keep these operating instructions for future in rooms or storage areas that are below ground level reference. Pass them on to possible new owners of the (cellars, etc.). It is advisable to keep only the cylinder appliance. being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, Positioning fireplaces, stoves, etc. ) which could raise the ! Keep packaging material out of the reach of children. It temperature of the cylinder above 50°C. can become a choking or suffocation hazard (see Fitting the appliance Precautions and tips). ! The appliance must be installed by a qualified professional Gas and mixed hobs are manufactured with type X degree protection against overheating. The following precautions according to the instructions provided. Incorrect installation must be taken when installing the hob: may cause harm to people and animals or may damage property. • Kitchen cabinets adjacent to the appliance and taller ! This unit may be installed and used only in permanently than the top of the hob must be at least 600 mm from the ventilated rooms in accordance with British Standard Codes edge of the hob. Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891 • Hoods must be installed according to their relative Current Editions. The following requirements must be installation instruction manuals and at a minimum observed: distance of 650 mm from the hob. • The room must be equipped with an air extraction system • Place the wall cabinets adjacent to the hood at a that expels any combustion fumes. This may consist of a minimum height of 420 mm from the hob (see figure). hood or an electric fan that automatically starts each time the appliance is switched on. If the hob is installed beneath a wall cabinet, the latter must be situated at a minimum of 700 mm 700mm min. 420mm min. above the hob (see figure). 600mm min. In a chimney stack or branched flue. Directly to • The installation cavity should have the dimensions (exclusively for cooking appliances) the Outside indicated in the figure. • The room must also allow proper air circulation, as air is Fastening hooks are provided, allowing you to fasten the needed for combustion to occur normally. The flow of air hob to tops that are between 20 and 40 mm thick. To must not be less than 2 m /h per kW of installed power. ensure the hob is securely fastened to the top, we 3 The air circulation system may recommend you use all the hooks provided. take air directly from the outside by means of a pipe with an inner 555 mm cross section of at least 100 cm ; 55 mm 2 A the opening must not be vulnerable to any type of 475 mm Examples of ventilation holes blockages. for comburant air. The system can also provide the Adjacent Room to be air needed for combustion Hook fastening diagram Room Vented indirectly, i.e. from adjacent rooms fitted with air circulation tubes as described above. However, these rooms must not be communal Enlarging the ventilation slot rooms, bedrooms or rooms that between window and floor. Hooking position Hooking position may present a fire hazard. for top H=20 mm for top H=30 mm • Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, rooms containing LPG cylinders must 2
Front Connecting the supply cable to the mains Install a standardised plug corresponding to the load GB indicated on the data plate. The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the Hooking position Back circuit-breaker). The supply cable must not come into for top H=40 mm contact with surfaces with temperatures higher than 50°C. ! Use the hooks contained in the “accessory pack” ! The installer must ensure that the correct electrical • Where the hob is not installed over a built-in oven, a connection has been made and that it is compliant with wooden panel must be installed as insulation. This safety regulations. must be placed at a minimum distance of 20 mm from Before connecting to the power supply, make sure that: the lower part of the hob. • The appliance is earthed and the plug is compliant with the law. Ventilation • The socket can withstand the maximum power of the To ensure adequate ventilation, the back panel of the appliance, which is indicated on the data plate. cabinet must be removed. It is advisable to install the oven so that it rests on two strips of wood, or on a • The voltage is in the range between the values indicated completely flat surface with an opening of at least 45 x on the data plate. 560 mm (see diagrams). • The socket is compatible with the plug of the appliance. If the socket is incompatible with the plug, ask an authorised technician to replace it. Do not use extension cords or multiple sockets. 560 mm. 45 mm. ! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible. ! The cable must not be bent or compressed. ! The cable must be checked regularly and replaced by When installing the cooktop above a built-in oven authorised technicians only (see Assistance). without forced ventilation, ensure that there are air ! The manufacturer declines any liability should these safety inlets and outlets for ventilating the interior of the measures not be observed. cabinet adequately. Gas connection The appliance should be connected to the main gas supply or to a gas cylinder in compliance with current national regulations. Before carrying out the connection, make sure the cooker is compatible with the gas supply you wish to use. If this is not the case, follow the instructions indicated in the paragraph “Adapting to different types of gas.” When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations. ! Check that the pressure of the gas supply is consistent Electrical connection with the values indicated in Table 1 (“Burner and nozzle Hobs equipped with a three-pole power supply cable are specifications”). This will ensure the safe operation and designed to operate with alternating current at the voltage longevity of your appliance while maintaining efficient and frequency indicated on the data plate (this is located energy consumption. on the lower part of the appliance). The earth wire in the cable has a green and yellow cover. If the appliance is to Connection with a rigid pipe (copper or steel) be installed above a built-in electric oven, the electrical ! Connection to the gas system must be carried out in such connection of the hob and the oven must be carried out a way as not to place any strain of any kind on the separately, both for electrical safety purposes and to appliance. make extracting the oven easier. 3