ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ ENGLISH PУССКИЙ Кондиционер (сплит-система) для бытового использования Внутренний блок RAS-07, 10, 13, 16EKV Наружный блок RAS-07, 10, 13, 16EAV 1110255116 1110255116_EN.indd 1 2/13/13 2:47 PM
PRECAUTIONS FOR SAFETY 3 AIRFLOW DIRECTION ? Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealer or the specialist to do this. 1 Press FIX : Move the louver in 0 ? Turning off the power supply will not prevent potential the desired vertical direction. electric shock. DANGER ? The appliance shall be installed in accordance with national wiring regulation. ? Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be Press SWING : Swing the air incorporated in the ?xed wiring. 2 automatically and press again to ? Do not expose your body directly to cool air for a long stop. time. ? Do not insert your ?nger or any article into the air inlet/ outlet. For horizontal direction, adjust ? When an abnormality (burning smell, etc.) occurs, stop 3 manually. the air conditioner and disconnect the power supply or turn off the breaker. ? This appliance is not intended for use by persons Note: 0 (including children) with reduced physical, sensory or ? Do not move the louver manually by others. mental capabilities, or lack of experience and knowledge, ? The louver may automation positioning by some operation mode. WARNING unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. ? Children should be supervised to ensure that they do not play with the appliance. 4 REMOTE CONTROL ? Do not use any refrigerant different from the one speci?ed for complement or replacement. Otherwise, abnormally 1 Infrared signal emitter 1 high pressure may be generated in the refrigeration 2 Start/Stop button cycle, which may result in a failure or explosion of the product or an injury to your body. 3 Mode select button (MODE) 4 Temperature button (TEMP) ? Do not wash the unit with water. It may cause an electric shock. 5 Fan speed button (FAN) ? Do not use this air conditioner for other purposes such as 6 Swing louver button (SWING) 3 4 preserving food, breeding animal, etc. 7 Set louver button (FIX) 2 ? Do not step or put anything on the indoor/outdoor unit. It 8 Off timer button (OFF) 7 6 may cause an injury or damage the unit. 9 High power button (Hi-POWER) 9 5 ? Do not touch aluminium ?n because it may cause an ! Economy button (ECO) 8 ! injury. 0 ? Before cleaning the unit, turn off the main switch or the " Clear button (CLEAR) # " circuit breaker. CAUTION ? When the unit won’t be used for a long time, turn off the # Check button (CHECK) main switch or the circuit breaker. ? It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time. ? The manufacturer shall not assume any liability for the 5 AUTOMATIC OPERATION damage caused by not observing the description of this manual. To automatically select cooling, heating, or fan only operation 1. Press MODE : Select A. 1 INDOOR UNIT DISPLAY 2. Press : Set the desired temperature. 3. Press FAN : Select AUTO, LOW , LOW+ , MED , MED+ , or HIGH . 1 TIMER (Yellow) 2 OPERATION (Green) 3 RESET button COOLING / HEATING / FAN ONLY 6 OPERATION 1. Press MODE : Select Cool , Heat , or Fan only . 2. Press : Set the desired temperature. Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only: No temperature indication 2 PREPARATION BEFORE USE 3. Press FAN : Select AUTO, LOW , LOW+ , MED , MED+ , or HIGH . Preparing Filters 1. Open the air inlet grille and remove the air ?lters. 2. Attach the ?lters. (see detail in the accessory 7 DRY OPERATION sheet). Loading Batteries (when use wireless operation.) For dehumidi?cation, a moderate cooling performance is controlled 1. Remove the slide cover. automatically. 2. Insert 2 new batteries (AAA type) following the (+) 1. Press MODE : Select Dry . and (–) positions. Remote Control Reset 2. Press : Set the desired temperature. 1. Remove the batteries. 2. Press . 3. Insert the batteries. 8 Hi-POWER OPERATION To automatically control room temperature and air?ow for faster cooling or heating operation (except in DRY and FAN ONLY mode) Press Hi POWER : Start and stop the operation. 2/13/13 2:48 PM 1110255116_EN.indd 2 2/13/13 2:48 PM 1110255116_EN.indd 2
9 ECO OPERATION 15 OPERATION AND PERFORMANCE 1. Three-minute protection feature: To prevent the unit from being To automatically control room to save energy (except in DRY and FAN ONLY mode) activated for 3 minutes when suddenly restarted or switched to ON. 2. Preheating operation: Warm up the unit for 5 minutes before the Press : Start and stop the operation. heating operation starts. Note: Cooling operation; the set temperature will increase automatically 1 3. Warm air control: When the room temperature reaches the set degree/hour for 2 hours (maximum 2 degrees increase). For heating temperature, the fan speed is automatically reduced and the outdoor operation the set temperature will decrease. unit will stop. 4. Automatic defrosting: Fans will stop during defrost operation. 5. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air 10 TEMPORARY OPERATION conditioner. EN 6. Consideration for accumulated snow: Select the position for outdoor In case of the misplaced or discharged remote control unit where it will not be subjected to snow drifts, accumulation of ES ? Pressing the RESET button, the unit can start leaves or other seasonal debris. or stop without using the remote control. 7. Some minor cracking sound may occur when unit operating. This is ? Operation mode is set on AUTOMATIC normal because the cracking sound may be caused by expansion/ operation, preset temperature is 25°C and fan contraction of plastic. FR operation is automatic speed. Note: Item 2 to 6 for Heating model Air conditioner operating conditions PT Temp. Outdoor Temperature Room Temperature Operation RU 11 TIMER OPERATION Heating –15°C ~ 24°C Less than 28°C Cooling –10°C ~ 46°C 21°C ~ 32°C Set the timer when the air conditioner is operating. Dry –10°C ~ 46°C 17°C ~ 32°C TR Setting the OFF timer 1 Press OFF for enter OFF timer setting. 16 TROUBLESHOOTING (CHECK POINT) The unit does not operate. Cooling or Heating is abnormally low. 2 ? The power main switch is ? The ?lters are blocked with dust. Press for select desired OFF timer. (0.5 - 12 hrs) turned off. ? The temperature has been set ? The circuit breaker is improperly. 3 Press OFF for set OFF timer. activated to cut off the power ? The windows or doors are opened. supply. ? The air inlet or outlet of the outdoor ? Stoppage of electric current unit is blocked. ? ON timer is set. ? The fan speed is too low. 4 Press OFF again for cancel OFF timer. ? The operation mode is FAN or DRY. 17 REMOTE CONTROL A-B SELECTION 12 AUTO RESTART OPERATION To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly. To automatically restart the air conditioner after the power failure (Power of the unit must be on.) Remote Control B Setup. Setting 1. Press RESET button on the indoor unit to turn the air conditioner ON. 1. Press and hold the RESET button on the indoor unit for 3 seconds to 2. Point the remote control at the indoor unit. set the operation. (3 beep sound and OPERATION lamp blink 5 time/ 3. Push and hold button on the Remote Control by the tip of the sec for 5 seconds) pencil. “00” will be shown on the display. (Picture 1) 2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not 4. Press MODE during pushing . “B” will show on the display and blink) “00” will disappear and the air conditioner will turn OFF. The Remote • In case of ON timer or OFF timer are set, AUTO RESTART Control B is memorized. (Picture 2) OPERATION does not activate. Note: 1. Repeat above step to reset Remote Control to be A. 2. Remote Control A has not “A” display. 3. Default setting of Remote Control from factory is A. 13 MAINTENANCE 0 Firstly, turn off the circuit breaker. Indoor Unit and Remote Control ? Clean the indoor unit and the remote control with a wet cloth when 1 2 needed. ? No benzine, thinner, polishing powder or chemically-treated duster. SELF CLEANING OPERATION 14 (COOL AND DRY OPERATION ONLY) To protect bad smell caused by the humidity in the indoor unit. 1. If the button is pressed once during “Cool” or “Dry” mode, the fan will continue to run for other 30 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit. 2. To stop the unit immediately, press the more 2 times within 30 seconds. 2/13/13 2:48 PM 1110255116_EN.indd 3 2/13/13 2:48 PM 1110255116_EN.indd 3