На сайте 124199 инструкций общим размером 502.84 Гб , которые состоят из 6278836 страниц
Руководство пользователя TIMBERK TIM 05 HP4. Основные функции, характеристики и условия эксплуатации изложены на 24 страницах документа в pdf формате.
Доступно к просмотру 24 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Instruction manual Electric floor standing air onditioner ortable ( ) type (single case) /Models ( ) Electric floor air conditioner portable type (single case) AC TIM 05H P4 AC TIM 07H P4 AC TIM 09H P4 AC TIM 09HE P4 17 18 Outlook of devices, aslo colour scores can be revised without any special advance notices.
1.Important information......................................................................................................... 2 9. Do not use adapters and extension cords to connect your portable air 2.Precautions................................................................................................................................ 2 conditioner. 3.Technical characteristics...................................................................................................... 3 10. Improper installation and use of this air conditioner may lead to severe 4.Description of portable air conditioner...................................................................... 4 injuries or damage to your property. 5.Control of portable air conditioner................................................................................. 5 11. Any maintenance must be performed by a specialized company and Control panel (for AC TIM 05H P4, AC TIM 07H P4, AC TIM 09H P4)................. 5 qualified specialists. Control panel (for AC TIM 09HE P4).................................................................................... 5 Remote control (for AC TIM 09HE P4)............................................................................... 6 2. PRECAUTIONS 6.Maintenance............................................................................................................................ 7 1. Do not block vents! 7.Service life.................................................................................................................................. 8 2. Make sure the inlet and outlet vent is not blocked. 8.Rules of disposal...................................................................................................................... 8 3. Do not insert foreign objects into the air diffuser of the air conditioner. It is 9.Helpful advice.......................................................................................................................... 8 very dangerous since the fan rotates at high speed. 10.Troubleshooting...................................................................................................................10 4. Install the device only on a horizontal surface to prevent condensed water leakage. 5. Do not install the floor-mounted air conditioner in the following places: - in places exposed to direct sunlight; Dear Customer! - in the vicinity of open fire sources; Thank you for a shrewd choice and purchase of Timberk portable electric air - in the vicinity of other operating heating devices; conditioner. - in places where water or steam splashes can contact the device; It will serve you for a long time. - in rooms with increased humidity; - close to swimming pools, bathrooms and shower rooms. 1. IMPORTANT INFORMATION 6. Do not use the device in an explosive or corrosive environment. Do not store gasoline and other volatile flammable liquids near the air conditioner 1. Please read this instruction manual carefully prior to installation and it is very dangerous! operation of a portable air conditioner. 7. Use the device to cool down air at ambient temperature 17-32°C. To use 2. To avoid damage to the air conditioner and voiding your guarantee, the device as a heater the room temperature must be 5-23°C. before start using the air conditioner put the device in a vertical position (as shown on the cover of this instruction manual) for at least 2 hours prior to 8. Regularly clean filters to ensure efficient operation of the device. operation. 9. To ensure reliable operation of the compressor, do not tilt the air 3. There may be misprints in the text and digital symbols in this manual. conditioner. 4. If after reading the manual you would still have questions regarding 10. If the device is disconnected, restarting must be performed not sooner functioning and operation of the device, please contact the seller or a than in 3.5 minutes to prevent the compressor failure. specialized service center for clarifications. 11. At least 10 A current is required for the compressor to operate. To avoid 5. The device has a tag indicating all necessary technical data and other overheating and fire risk, as well as damage to the inner electrical circuit, do useful information about the device. not connect the device through extension cords. 6. Use the device only as designated by this manual. 12. The device is designed to cool, heat and dry air only in residential 7. Prior to installation of the portable air conditioner, not connecting it to the conditions and cannot be used for industrial purposes. mains, check and make sure that the mains socket for the air conditioner has 13. To avoid electric shock, a damaged power cord must be replaced only by a grounding pin and is properly grounded. an authorized service center and qualified specialists. 8. In case there is no grounding pin in your mains, operation of the portable 14. Prior to disposal of the device, it is necessary to remove batteries from it, air conditioner is life-threatening. after that they can be safely disposed. 2 www.timberk.com electric floor standing air onditioner ortable type (single case)
ENGLISH 15. Connect the air conditioner only to 220-230 V 50 Hz mains. If necessary, 3.Technical characteristics ask your power suppliers to give characteristics of your mains. Tab.1 16. The appliance is not intended for use by children and persons with reduced physical, sensory or mental capabilities, or a lack of experience and Наименование AC TIM 05H P4 AC TIM 07H P4 AC TIM 09H P4 09H P4 AC TIM 09HE P4 AC TIM knowledge, unless they have been given supervision or instruction Capacity (cooling), Wh(kW) 5000 (1,5) 7000 (2,0) 9000 (2,6) 9000 (2,6) concerning use of the appliance by an individual responsible for their safety. Capacity (heating), Wh(kW) 5000 (1,5) 7000 (2,0) 9000 (2,6) 9000 (2,6) Children should be supervised to ensure that they do not play with the Power consumption (cooling), W 650 900 1100 1100 appliance. Power consumption (heating), W 500 700 950 950 Supply voltage V/Hz 220/50 220/50 220/50 220/50 Current (cooling/heating), A 3,0/2,3 4,1/3,2 5,0/4,3 5,0/4,3 IMPORTANT! Air ?ow m 3 /h 280 280 360 360 Efficient heating and cooling require to: Dehumidi?cation capacity, I/day 25 30 50 50 1) Ensure at least 50 cm of free space on the filtering side of the unit Noise level, dB(A) 50 50 52 52 (Fig. 1). Refregerant R410 R410 R410 R410 2) Extend the air duct not more than 400 mm. The hose must be Energy ef?ciency class B B B B (cooling/heating) located in parallel to the surface. It is forbidden to fold the hose! (see Electrical protection I class I class I class I class Fig. 2) Degree of moisture protection IPХ0 IPХ0 IPХ0 IPХ0 3) Upon defreezing a DF symbol is indicated on the display screen Net weight, kg 22,0 22,5 23,0 23,0 (except for AC TIM 05 P4, AC TIM 07 P4, AC TIM 09H P4). Gross weiht, kg 23,5 24,0 24,5 24,5 Device dimensions, mm 300x455x630 300x455x630 300x455x630 300x455x630 Package dimensions, mm 330x485x660 330x485x660 330x485x660 330x485x660 NOTICE. The manufacturer reserves the right to make changes in the design, scope of delivery, product manufacturing technology, as well as change its technical characteristics to improve its consumer and technical properties without prior notice. SCOPE OF DELIVERY Fig. 1 1. Household air conditioner 1 pc. 2. Remote control* (batteries are not supplied, 1,5V UM4 AAA CR03 batteries are required) 1 pc. 3. The adapter for air duct 1 pc. 4. Air outlet hose 1 pc. 5. Removable grille 1 pc. * - only for AC TIM 09HE P4. Fig. 2 www.timberk.com electric floor standing air onditioner ortable type (single case) 3