На сайте 124091 инструкция общим размером 502.34 Гб , которые состоят из 6272475 страниц
Руководство пользователя TIMBERK THU UL 09 (BU). Основные функции, характеристики и условия эксплуатации изложены на 16 страницах документа в pdf формате.
Доступно к просмотру 16 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Instruction manual Electric humidifier /Model THU UL 0 9 ( W) THU UL 0 9 ( BL) THU UL 0 9 ( O) THU UL 0 9 ( BU) Outlook of devices, aslo colour scores can be revised without any special advance notices. AA71
2. Safeguards Dear customer! We thank you for your happy choice! You've bought an air humidifier Before startup of the humidifier, please, study this manual carefully and Timberk. It will serve you for a long time. Please, read this manual carefully keep it for further use. before operating the device! While using the appliance, it is necessary to observe some precautions. Improper operation due to disregard to precautions may result in Contents personal injury of user or other people, as well as to damaging of their 2 property. The humidifier is designed for work in habitable rooms with 2 observation of the stated operation conditions. Using of the humidifier 1.Important information........................................................... 3 not for its intended purpose may create situations dangerous to life and 2.Safeguards........................................................................... health. The electric appliance, while in operation, should be under 3 supervision, especially if it is used in a room with children. The appliance 3.Specification......................................................................... 3 is not intended for use by persons (including children) with physical, 4.Appliance description ........................................................... 4 sensory or mental disabilities, or having insufficient experience and 5.List of parts.............................................................. 7.Appliance operation 4 knowledge, if they are not under supervision and did not receive 6.Filling tank with water .............................................................. 5 instructions for use of the appliance from a person responsible for their safety. Please, make sure that children do not play with the appliance. 5 only in accordance with the user's manual. 8. artridge filter for water softening ........................................................... 5 Never use the humidifier with a damaged power cord or plug and if the 9.Cleaning and maintenance ................................................................... 5 humidifier is broken or damaged by falling or in other circumstances. 10.Troubleshooting ........................................................................... 11.Utilization........................................................................... 1. Important information The humidifier should be operated only in the fully assembled condition. To avoid a burn, do not touch a membrane of the operating humidifier The manufacturer reserves the right to make modifications in design, (for ultrasonic models). High frequency of oscillations results in heating configuration or manufacturing process of the device in order to of the membrane. High-frequency oscillations of the ultrasonic improve its properties. humidifier membrane are noiseless and safe for people and pets. There may be some misprints in the text and digital notations of this To avoid the electric shock, the damaged power cord should be replaced manual. only in authorized service centers by qualified specialists. If you have any answers concerning operation of the appliance after To avoid the electric shock, do not place the power cord near heating you've read the manual, please, apply to a shop assistant or to a appliances and inflammable or combustible materials. specialized service center for explanations. To avoid traumas and property damage, do not try to repair the The article has a label showing all the necessary specification data and humidifier by yourself. other useful information about the appliance. Unplug the humidifier in the following cases: before discharge or filling Use the appliance only for its intended purpose indicated in this manual. of a tank with water; before cleaning and maintenance; before The humidifier is designed for air humidification indoors. assembling/disassembling of elements; before displacement of the Relative air humidity for comfortable conditions should be between 40 humidifier. and 60%. Install the humidifier on flat dry surface. Insufficient air humidity results in exsiccation of mucous membranes, Outgoing steam may damage exposed surfaces. Do not install the which in turn causes decrease in immunity, headache, cracking of lips, humidifier on the floor, as well as in close proximity to heating sandpaper in the eyes, favors infection and respiratory tract diseases, appliances, walls, furniture and other objects. promotes exhaustion, leads to increased fatigue of eyes and decline of The manufacturer and vendor are not responsible for damages caused attention concentration, has an adverse effect on pets and house-plants, by incorrect position of the humidifier. leads to the growth of dust formation and increase of electrostatic charge of synthetic textiles. 2 www.timberk.com electric humidifier
ENGLISH The humidifier should be installed on a rise e.g. on a table, pedestal, 4. Appliance description etc. Never fill the water in the humidifier through a diffuser. Pic. 1 Do not immerse the humidifier in water or other liquids. Do not install the humidifier in a passage or in other places, where it can be touched, overturned, etc. If the humidifier is not in use, unplug it. Do not lay a power cable under 1 a carpet or other objects. While placing the humidifier, be careful that you do not touch the power cable by accident. Do not use the humidifier in damp rooms. 2 Prevent the ingress of foreign objects into the humidifier. 3 8 Do not block an air intake and the diffuser with foreign objects. Do not sit or stand on the humidifier and do not put heavy objects on it. 9 To avoid the damage of the humidifier, do not mix the water used for humidification with essential oils, preservation agents, flavouring materials and other foreign substances. The manufacturer and vendor 3 10 are not responsible for damages of the humidifier caused by nonfulfillment of this requirement. 11 While unplugging the humidifier, do not pull the power cable and do not touch it with wet hands. 4 12 5 3. Specification 13 Table 1. 6 Humidification capacity, ml/h 180 14 Supply voltage, V/Hz 220/50 Tank volume, l 1,8 7 Power consumption, W 16 15 Nominal current, A 0,08 Moisture protection class rating IPX0 Electrical protection class rating ll Appliance dimensions, mm 260 155 240 Package dimensions, mm 300 205 285 Net weight, kg 1,15 Gross weight, kg 1,7 Recommended floor space, m 2 20-25 The manufacturer reserves the right to change the set-list of the device (including liquid and powder 5 components) for different supplies without prior notice. The changes either in no way influence the basic technical parameters of the device or may improve them, and also not violate the legislation or quality standards of the countries of manufacture, transit and selling. The changes in the set-list may result in changing of the weight and dimensions of the device, but not more than by +\- 5-20% (depending on the product category) www.timberk.com electric humidifier 3