На сайте 124213 инструкций общим размером 502.86 Гб , которые состоят из 6279321 страницы
Руководство пользователя TIMBERK TEF F12 FH5. Основные функции, характеристики и условия эксплуатации изложены на 36 страницах документа в pdf формате.
Доступно к просмотру 36 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Instruction manual Руководство по эксплуатации Электрический Electric air кондиционер воздуха, conditioner, сплит-система split system Модели/Models: Электрический кондиционер воздуха, сплит-система (внутрен- ний блок) Electrical air conditioner, split system (indoor unit) • AC TIM 12LC ST3 • AC TIM 18LC ST3 • AC TIM 24LC ST3 • AC TIM 36LC ST3 • AC TIM 48LC ST3 • AC TIM 60LC ST3 Электрический кондиционер воздуха, сплит-система (наружный блок) Electrical air conditioner, split system (outdoor unit) • AC TIM 12LC ST3-O1 • AC TIM 18LC ST3-O1 • AC TIM 24LC ST3-O1 • AC TIM 36LC ST3-O1 • AC TIM 48LC ST3-O1 • AC TIM 60LC ST3-O1 Outlook of devices, aslo colour scores can be revised without any special advance notices. Руководство по эксплуатации включает в себя гарантийный талон Производитель вправе менять внешний вид прибора и цвето- вую гамму прибора без специального уведомления.
CONTENTS Dear customer! 1. Important information 2 We thank you for your happy choice and buying of a domestic air 2. Safeguards 2 conditioner TImberk. It will serve you for a long time. 3. Specifications 4 Is intended for cooling, heating, dehydration of air in domestic 4. Appliance description 6 premises. 5. Delivery set 6 6. Appliance control 6 7. Operating modes 8 1. IMPORTANT INFORMATION 8. Maintenance 9 9. 9. Troubleshooting 10 10. Transportatiom and storage 10 It is designed for cooling in residential buildings. 11. Service life 10 The manufacturer reserves the right without notice the buyer to make 12. Utilization rules 10 changes in design, equipment or technology to manufacture products in order to improve its properties. The text and figures are given instruction may be a misprint. IMPORTANT! If after reading of this manual you have any questions concerning work and operation of the appliance, please, refer to a shop assistant or to a specialized service center for further explanations. The article has a label with all the needed technical data and other useful information about the appliance. Use the appliance only for its intended purpose indicated in this manual. 2. SAFEGUARDS 1. Do not attempt to install the air conditioner. Consult a qualified technician for installation. 2. When using conditioner, you must be a number of precautions. Improper use by ignoring safety precautions can result in damage to health user and 2 www.timberk.com • Electric air conditioner
others, as well as damage to their property. power. 3. The appliance should be monitored during its operation, especially when 22. Do not press the button on the remote control far from it are children. (PDU), than anything other than your fingers. 4. Do not insert fingers or foreign objects through the air release lattice 23. Do not use for purposes not covered by this manual. indoor and outdoor units, as this can lead to injury from the rotating fan. 5. Do not allow children to independently include air conditioning. Children can include air conditioning only with adult supervision. 6. Do not try to repair the air conditioner. Domestic air conditioning units are under stress, it is dangerous to life! To repair the product, contact an authorized service center. 7. Do not use if it is defective, or if it is dropped or damaged. 8. Do not open the front panel of the device during its operation. 9. Do not disassemble or modify the device. 10. Immediately turn off the air conditioner from the electrical network if it goes from strange odors or smoke. 11. Do not spray or pour water or other liquids on the air conditioner. 12. Always unplug the air conditioner from the mains during a thunderstorm. 13. Always unplug the air conditioner from the mains when not in use. 14. Before cleaning and maintenance of the air conditioner disconnect from the mains. Cleaning and maintenance performed in accordance with the instructions of this manual. 15. To ensure the efficient operation of air conditioning using it in a temperature-humidity conditions specified in this manual. 16. Do not use dangerous chemicals to clean the device and do not let them hit on the device. 17. When removing the air filter does not touch the metal parts of the device. 18. To avoid overheating and fire risk and damage the internal electrical network, do not change the length of the cord and do not connect the device via electrical extension cords. an extension cord. However, you can use 19. To avoid electrical hazards, damaged power cord must be changed only at authorized service centers qualified professionals. 20. To avoid risk of electric shock, do not place the power cord near a heater and flammable or combustible substances. 21. Do not start or stop the unit by connecting or disconnecting electrical www.timberk.com • Electric air conditioner 3