На сайте 124245 инструкций общим размером 502.98 Гб , которые состоят из 6280614 страниц
Руководство пользователя TIMBERK Evolution WHP. Основные функции, характеристики и условия эксплуатации изложены на 24 страницах документа в pdf формате.
Доступно к просмотру 24 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Instruction manual Руководство по эксплуатации TOR 21...BCL TOR 11...SM TOR 21...BC Электрический Electric маслонаполненный oil filled радиатор radiator Модели/Models: TOR 21.1206 BC TOR 21.1206 BTA TOR 21.1507 BC TOR 21.1507 BTA TOR 21.2009 BC TOR 21.2009 BTA TOR 21.2512 BC TOR 21.2512 BTA TOR 21...ACX TOR 21...BTA TOR 21.1206 BCL TOR 21.1005 ACX TOR 21.1507 BCL TOR 21.1507 ACX TOR 21.2009 BCL TOR 21.1809 ACX TOR 21.2512 BCL TOR 21.2211 ACX TOR 31.1606 QT TOR 21.1005 SLX TOR 31.1907 QT TOR 21.1507 SLX TOR 31.2409 QT TOR 21.1809 SLX TOR 31.2912 QT TOR 21.2211 SLX TOR 11.0606 SM TOR 21...SLX TOR 31...QT TOR 11.1009 SM TOR 11.1211 SM Руководство по эксплуатации включает в себя гаратийный талон Outlook of devices, aslo colour scores can be revised without any special advance notices. Производитель вправе менять внешний вид прибора и цветовую гамму при- бора без специального уведомления.
Dear customer! IMPORTANT! Thank you for your good choice! You purchased a Timberk oil filled radiator. We did everything for the unit to operate reliably Important safeguards and instructions contained in for a long time. this manual do not include all possible modes and situations. It is necessary to understand that common Timberk electric oil filled radiator is designed to heat the air sense, caution and accuracy are factors, which cannot and create a comfortable environment indoors during cold be ‘built-in’ any product. season (early spring, fall, winter). The radiator is very easy-to- use, easy to install, and also has an increased heat transfer and These factors should be considered by a person, who an efficient air flow distribution. Besides, Timberk Professional is interested in the proper operation of the appliance. oil filled radiators are additionally equipped with an air ionizing The manufacturer is nor responsible for damage of the function. The built-in air ionizer can operate independently of appliance or its parts during transportation, as a result the air heating mode. of incorrect installation or voltage fluctuations, as well as when any part of the appliance has been changed You must install the oil filled radiator only vertically and only on or modified. a rigid surface (for example, on the floor) in a place, where it is possible to connect to 220~V, 50Hz single-phase power supply wiring with an earth circuit. 2. SAFEGUARDS 1. IMPORTANT INFORMATION When using the oil-filled radiator several safety precautions should be followed in order to reduce the risk of fire, electric shock and injury to persons. Incorrect operation due to disregard to precautions may cause Please, read this manual carefully before use of the electric oil-filled radiator. harm to health of the user and other persons, as well as damage to their This manual contains important information regarding your safety, as well property. as recommendations concerning the correct use and maintenance of this 1. Read this manual carefully before using the radiator. appliance. 2. The radiator is very hot when in use. To avoid burns, do not let bare skin Keep this manual together with a guarantee slip, cash register receipt and, touch hot surfaces. Keep the radiator at least 0.9 m from furniture, pillows, if possible, carton and packaging material. bedding, paper, clothes, curtains and other combustible materials. Let the The radiator you have bought may slightly differ from that described in the radiator cool down before moving. When moving radiator, use a built-in manual, but it does not affect its use and operation procedures. handle. Please, read this manual carefully before use of the electric oil-filled radiator. 3. Extreme caution is necessary when the radiator is used near children This manual contains important information regarding your safety, as well and whenever the radiator is left operating and unattended. as recommendations concerning the correct use and maintenance of this 4. Always unplug the radiator when not in use. appliance. 5. Do not operate radiator with a damaged cord or plug. To avoid the Keep this manual together with a guarantee slip, cash register receipt and, damage of electric shock, damaged cord should be replaced only in if possible, carton and packaging material. authorized service centers of the manufacturer by qualified specialists. The radiator you have bought may slightly differ from that described in the 6. Do not use radiator outdoors. manual, but it does not affect its use and operation procedures. 7. This radiator is not intended for use in bathrooms, laundry areas or other similar wet indoor locations. Never locate radiator where it may fall into a 2 www.timberk.com • electric oil filled radiator
bathtub or other water container. 8. Do not run cord of the radiator under carpeting and do not press it with 3. SPECIFICATIONS furniture. Arrange cord where it will not be tripped over. 9. To shut-off the radiator, use a power switch. Do not switch on and switch Specifications of the oil-filled radiator are shown in Table 1. off the appliance by connection and disconnection of electric supply. Table 1 10. Do not insert your fingers and do not allow foreign objects to enter any Power Power supply, Rated Number Net weight, Device ventilation or exhaust opening as it may cause an electric shock or damage Model consumption, V/Hz current A of fins kg dimensions, mm W the radiator. 11. To prevent a possible fire, do not block air intakes or exhaust in any TOR 21.1206 BC 1200 220~/50 5,4 6 6,3 310x235x625 manner. Do not dry your clothes on the radiator! Do not use it on soft TOR 21.1507 BC 1500 220~/50 6,8 7 7,2 350x235x625 surfaces, like bed, where openings may become blocked. Use the radiator TOR 21.2009 BC 2000 220~/50 9,1 9 9 430x235x625 only on flat dry surface. TOR 21.2512 BC 2500 220~/50 11,4 12 11,7 550x235x625 12. The radiator has hot sparking parts inside. Do not use it in areas where gasoline, paint or other flammable liquids are used or stored. 13. Use this radiator only as described in this manual. Any other use not TOR 21.1206 BCL 1200 220~/50 5,4 6 6,3 310x235x625 recommended by the manufacturer may cause fire, electric shock or injury TOR 21.1507 BCL 1500 220~/50 6,8 7 7,2 350x235x625 to persons. TOR 21.2009 BCL 2000 220~/50 9,1 9 9 430x235x625 14. Always unplug the radiator before cleaning. Do not submerge the TOR 21.2512 BCL 2500 220~/50 11,4 12 11,7 550x235x625 radiator. Never pull the cord. 15. Avoid the change of a cord and the use of an extension cord because it may cause overheat and a risk of fire, as well as damage of internal TOR 31.1606 QT 1600 220~/50 7,3 6 7,3 310X235X625 electrical network. However, if you have to use an extension cord, the cord TOR 31.1907 QT 1900 220~/50 8,6 7 8,2 340X235X625 shall be polarized, with conductor cross-section of at least 1.0 mm2 and TOR 31.2409 QT 2400 220~/50 10,1 9 9,9 415X235X625 rated not less than 1875 W. TOR 31.2912 QT 2900 220~/50 13,1 12 12,4 530X235X625 16. Connect the radiator only to the 220~V/50Hz electric network. If needed, find out the characteristics of your network from power supplier. 17. Install and operate the appliance only when upright. Do not operate the TOR 21.1206 BTA 1200 220~/50 5,4 6 6.6 280x235x600 appliance in the horizontal or on the slant. TOR 21.1507 BTA 1500 220~/50 6,8 7 7.4 310x235x635 18. The appliance is not intended for use by handicapped persons TOR 21.2009 BTA 2000 220~/50 9,1 9 9.0 370x235x635 (including children) with insufficient experience and knowledge, if they are TOR 21.2512 BTA 2500 220~/50 11,4 12 11.30 490x235x600 not under observation or have not been instructed in the use of appliance from a person responsible for their safety. Make sure that children do not play with the radiator. TOR 21.1005 ACX 1000 220~/50 4,5 5 4.8 250х235х600 TOR 21.1507 ACX 1500 220~/50 6,8 7 5.8 310х235х600 TOR 21.1809 ACX 1800 220~/50 8,2 9 6.8 385х235х600 TOR 21.2211 ACX 2200 220~/50 10 11 8.4 460х235х600 www.timberk.com • electric oil filled radiator 3