На сайте 124113 инструкций общим размером 502.43 Гб , которые состоят из 6273721 страницы
Руководство пользователя KUPPERSBERG V 939 C. Основные функции, характеристики и условия эксплуатации изложены на 24 страницах документа в pdf формате.
Доступно к просмотру 24 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Technical passporT паспорт технического изделия T 939, V 939, V 63 9, Т 669 WALL COOKER HOODS НАСТЕННЫЕ КУХОННЫЕ ВЫТЯЖКИ
Technical passporT english Wall cooker hood CONTENTS 1. APPEAL TO THE CUSTOMER ..........................................................................................3 2. IMPORTANT SAFETY INSTRUCTIONS ......................................................................3 3. MAINTENANCE AND INSTALLATION MANUAL ..................................................5 3.1. TECHNICAL CHARACTERISTICS AND DRAWINGS ..................................5 4. MAINTENANCE AND CLEANING ..................................................................................9 5. TROUBLESHOOTING ..........................................................................................................9 5.1. PROBLEM SOLVING ..................................................................................................9 2
english Technical passporT Wall cooker hood 1. APPEAL TO THE CUSTOMER install a disconnection switch to the Congratulations on your choice. We house installation, according to the are sure that this modern, functional local standards for installations. and practical appliance, made with top A Make sure a good ground quality materials, will fully satisfy your connection (this does not apply to class needs. II appliances, indicated accordingly on Please read every section of this the rate plate with ) INSTRUCTIONS MANUAL before using A Once the kitchen hood has been your kitchen hood for the ? rst time, to installed, ensure that the mains cable to ensure maximum performance from the network is not in contact with sharp the appliance and to avoid breakdowns, metal edges. which may be caused by incorrect use, as well as to allow any minor problems A The fumes should not be to be solved. extracted through pipes that are used To obtain optimum performance, to evacuate the fumes of gas (or another the external conduct must not be more fuel) operated devices. than FOUR METRES long, have no more A If the extractor fan is going to be than two 90° angles and its diameter used simultaneously with equipment must be at least 120. powered by a non-electric energy 2. IMPORTANT SAFETY source, e.g.: gas cookers, then the room INSTRUCTIONS must have suf? cient ventilation. A Please be aware of current local A Excessive fat accumulation in regulations with reference to domestic the kitchen hood and metal ? lters is a electrical ? ttings and gas eduction. ? re risk and may also cause dripping, A Verify that the tension and therefore the inside of the kitchen hood frequency of the network match those and the metal ? lters must be cleaned at indicated on the label located inside least once a month. the kitchen hood. A The lower part of the kitchen A If the supply cable is damaged it hood must be ? tted at least 65cm should be replaced by the manufacturer, over gas or mixed hobs. FOLLOW THE the after-sales service or a suitably HOBS. MANUFACTURER’S MINIMUM quali? ed person in order to avoid hazard.quali? ed person in order to RECOMMENDATIONS. This distance avoid hazard. can be reduced if this is indicated by A In case your cooker hood is not the manufacturer in the cooker hood provided with a plug for the mains instruction manual. connection or is not accessible in A Never leave gas hobs lit if normal conditions it is necessary to not covered by a container. The fat 3