Руководство пользователя LUNDAHL LL9206. Основные функции, характеристики и условия эксплуатации изложены на 2 страницах документа в pdf формате.
Доступно к просмотру 2 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Tibeliusgatan 7 International Domestic S-761 50 NORRTALJE Phone +46 - 176 13930 0176-13930 SWEDEN Fax +46 - 176 13935 0176-13935 Audio Transformer/Moving Coil Input Transformer LL9206 LL9206 is an input audio transformer for moving coil pickups. The transformer is built up from two coils, each coil with one secondary winding surrounded by two primary windings. This structure results in an excellent frequency response. All winding ends are available on the pins. Thus, the transformer can be used with a set of different turn’s ratios. The LL9206 is made with amorphous core material. As this type of core does not store energy (unlike e.g. conventional mu-metal cores) the low frequency resonance with external series capacitors is practically eliminated. Turns ratio: 1 + 1 + 1 + 1 : 10 + 10 Dims: (Length x Width x Height above PCB (mm)) 30 x 22.5 x 14.5 Pin Layout (viewed from pins side) and windings schematics: 1 2 9 3 10 4 1 9 2 10 3 11 8 4 5 13 6 14 7 16 7 15 8 16 6 15 5 Can + Core 13, 14 Spacing between pins: 2.54 mm (0.1") Spacing between rows of pins: 22.86 mm (0.9") Weight: 27 g Rec. PCB hole diameter: 1.5 mm Static resistance of each primary (average): 10 W Static resistance of each secondary (average): 395 W Self resonance point : > 250 kHz Frequency response (@ -10 dBU, all in series. Source 50W , load 100 kW) : 10 Hz -- 25 kHz +/- 1 dB 10 Hz -- 90 kHz +/- 1.5 dB Distortion (primaries connected in series, source impedance 50W ): < 0.5% @ -2 dBU, 50 Hz Primary no load impedance @ 0 dBU, 50 Hz, all in series: 8 kW typically Core / Can: Amorphous Strip Core / Mu metal can Isolation between windings / between windings and core: 3 kV / 1.5 kV Turns ratio and possible use at different termination alternatives. When the LL9206 is used in Termination alternatives are shown on the next page MC pickup applications, Termination Turns Copper Resistance Possible Use please note that the primary Alternative ratio prim/sec side of the transformer must have a ground reference. A 1:5 40W / 790 W 400W / 10 kW B 1:5 10W / 200 W Not recommended C 1:10 10W / 790 W 100W / 10kW D 1:10 2.5W / 200 W Not recommended E 1:20 2.5W / 790 W 25W / 10kW R020201
LL9206 Termination Alternatives (Left side is input if not stated otherwise) (Pins side view) 1 9 1 9 2 10 2 10 3 A 11 3 11 4 4 5 CENTER TAP 13 5 A 13 6 14 6 14 7 15 7 15 8 16 8 16 CT 1 9 1 9 2 10 2 10 3 11 3 11 4 CT 4 B 5 B 13 5 CENTER TAP 13 6 14 6 14 7 15 7 15 8 16 8 16 1 9 1 9 2 10 2 10 3 11 3 11 4 CT 4 C 5 C 13 5 13 6 14 6 CENTER TAP 14 7 15 7 15 8 16 8 16 1 9 1 9 2 10 10 3 11 2 11 3 4 5 D 13 4 6 14 5 E 13 7 15 6 14 8 16 7 15 8 16 1 9 1 9 OUT 1 2 10 2 10 OUT 1 3 F 11 3 11 4 SPLIT IN 4 G 5 13 5 13 OUT 2 6 14 6 SPLIT 14 7 15 7 15 8 16 8 16 OUT 2