Tibeliusgatan 7 International Domestic LUNDAHL S-761 50 NORRTALJE Phone +46 - 176 13930 0176-13930 TRANSFORMERS SWEDEN Fax +46 - 176 13935 0176-13935 Audio Transformer LL1545A LL1545A is a general-purpose audio transformer with a variety of connection alternatives. The transformer is built up from two coils, each with a secondary winding surrounded by shields and two primary windings. This structure results in an excellent frequency response. The transformer can be used in many different applications such as a high impedance line input transformer (accepting signal levels of 22 dBU @ 40 Hz with primaries in series), for splitting or as a microphone input transformer. The LL1545A is made with a mu-metal core and is housed in a mu-metal can. Refer to page 2 of this sheet for termination alternatives. Turns ratio: 1 + 1 + 1 + 1 : 2 + 2 Dims: (Length x Width x Height above PCB (mm)) 37 x 22.5 x 14.5 Pin Layout (viewed from component side) and windings schematics: 1 8 16 2 9 7 15 3 6 LL1545A 14 4 10 5 13 11 4 (top view) 8 14 3 11 7 16 2 10 1 9 6 15 5 Can + Core 13 Spacing between pins: 2.54 mm (0.1") Spacing between rows of pins: 22.86 mm (0.9") Weight: 46 g Rec. PCB hole diameter 1.5 mm Static resistance of windings: 2-3 or 6-7 122 W 1-4 or 5-8 182 W 9-10 or 15-16 305 W Self resonance point: > 220 kHz Recommended load for best square-wave response (Termination alternative R4B:L4B over): 6.7 kW + 470 pF Frequency response (source 600W , 10 Hz - 70 kHz +/- 0.5 dB @ 0 dBU load (6.7 kW + 470 pF) in parallel with 56 kW ): Loss across transformer (at 1 kHz with termination as above): 0.3 dB Core: Mu-metal Isolation between windings / between windings and shields: 3 kV / 1.5 kV Data at different termination alternatives, showed on page 2 of this data sheet. Termination Alternatives Turns Copper Resistance Idle impedance Suggested Use THD < 0.2%@40 Hz ratio Prim/sec @40 Hz, 0dBU primary level / real source impedance R4B / R4U : L4B / L4U 1:1 610 W / 610 W 80 kW / 80 kW 10 kW / 10 kW 22 dBU / 600 W R2B / R2U : L2B / L2U 1:1 150 W / 150 W 20 kW / 20 kW 600 W / 600 W 16 dBU / 150 W R2B / R2U : L4B / L4U 1:2 150 W / 610 W 20 kW / 80 kW 600 W / 2.5 kW 16 dbU / 150 W R4B / R4U : L2B / L2U 2:1 610 W / 150 W 80 kW / 20 kW 10 kW / 2.5 kW 22 dBU / 37.5 W R4B / R4U : L1 4:1 610 W / 75 W 80 kW / 5 kW 10 kW / 600 W 22 dBU / 37.5 W R030220 LL1545A , page 1
9 1 10 2 11 3 4 Connection alternatives for LL1545A 13 5 14 6 Component side view 15 7 16 8 Component side view Connection: R4B Connection: R4U Connection: R2B Balanced source Unbalanced source Balanced source 9 9 9 10 10 10 11 11 11 13 13 13 14 14 14 15 15 15 16 16 16 Grounded at source Connection R2U Connection L4B Connection L4U Unbalanced source Balanced load Unbalanced load 9 1 1 10 2 2 11 3 3 4 4 13 5 5 14 6 6 15 7 7 16 8 8 Grounded at Centertap source Connection L2U Connection L2B Connection L1 Unbalanced load Balanced load 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 Centertap Turns Application Transformer Transformer ratio Input (primary) Output (secondary) 1:1 Line input to unbalanced circuits R4B / R4U L4U 1:2 Line input to unbalanced circuits R2B / R2U L4U 2:1 Line input to unbalanced circuits R4B / R4U L2U 1:1 Low impedance line input to unbalanced circuits R2B / R2U L2U 1:1 Line input to balanced circuits R4B / R4U L4B 1:2 Line input to balanced circuits R2B / R2U L4B 2:1 Line input to balanced circuits R4B / R4U L2B 1:1 Low impedance line input to balanced circuits R2B / R2U L2B R030206 LL1545A , page 2