На сайте 124171 инструкция общим размером 502.73 Гб , которые состоят из 6277477 страниц
Руководство пользователя ROTEL RC-1580. Основные функции, характеристики и условия эксплуатации изложены на 64 страницах документа в pdf формате.
Доступно к просмотру 62 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
RC-1580 Stereo Control Amplifier Preamplificateur stereo Stereo-Vorverstarker Preamplificador Estereofonico Stereo Voorversterker Preamplificatore Stereo Stereokontrollforstarkare eUA?AO O?A‰‚‡?EUAI?I?E UOEIEUAI? Owner’s Manual Manuel de l’utilisateur Bedienungsanleitung Manual de Instrucciones Gebruiksaanwijzing Manuale di istruzioni Instruktionsbok aIOU?UI?E? OOI?AO‚‡UAI?
2 RC-1580 Important Safety Instructions WARNING: There are no user serviceable parts inside. Refer Keep the component away from radiators, heat registers, stoves, all servicing to qualified service personnel. or any other appliance that produces heat. WARNING: To reduce the risk of fire or electric shock, do WARNING: The rear panel power cord connector is the mains not expose the unit to moisture or water. Do not expose the power disconnect device. The apparatus must be located in an unit to dripping or splashing. Do not place objects filled with open area that allows access to the cord connector. liquids, such as vases, on the unit. Do not allow foreign objects The unit must be connected to a power supply only of the type to get into the enclosure. If the unit is exposed to moisture, or and voltage specified on the rear panel. (USA: 120 V/60Hz, a foreign object gets into the enclosure, immediately disconnect EC: 230V/50Hz) the power cord from the wall. Take the unit to a qualified service person for inspection and necessary repairs. Connect the component to the power outlet only with the supplied power supply cable or an exact equivalent. Do not Read all the instructions before connecting or operating the modify the supplied cable. A polarized plug has two blades, with component. one wider than the other. A grounding plug has two blades plus Keep this manual so you can refer to these safety instructions. a third grounding prong. These are provided for your safety. Heed all warnings and safety information in these instructions Do not defeat grounding and/or polarization safety provisions. and on the product itself. Follow all operating instructions. If the supplied plug does not fit your outlet, please consult an electrician for replacement of the obsolete outlet. Do not use Clean the enclosure only with a dry cloth or a vacuum cleaner. extension cords. Do not use this unit near water. The main plug of the power cordset is a disconnect device of the You must allow a minimum 10 cm or 4 inches of apparatus. In order to completely disconnect the apparatus from unobstructed clearance around the unit. the supply mains, the main plug of the power cordset should be unplugged from the mains (AC) outlet. The stand-by LED Rotel products are designed to comply with indicator will not be lit up to show the power cord is unplugged. international directives on the Restriction of The disconnect device shall remain readily operable. Hazardous Substances (RoHS) in electrical and Do not route the power cord where it will be crushed, pinched, electronic equipment and the disposal of Waste bent, exposed to heat, or damaged in any way. Pay particular Electrical and Electronic Equipment (WEEE). The attention to the power cord at the plug and where the cord exits crossed wheelie bin symbol indicates compliance the back of the unit. and that the products must be appropriately The power cord should be unplugged from the wall outlet during recycled or processed in accordance with these a lightning storm or if the unit is to be left unused for a long directives. period of time. This symbol means that this unit is double Use only accessories specified by the manufacturer. insulated. An earth connection is not required. Use only with a cart, stand, rack, bracket Do not place the unit on a bed, sofa, rug, or similar surface that or shelf system recommended by Rotel. Use could block the ventilation openings. If the unit is placed in a caution when moving the unit in a stand or bookcase or cabinet, there must be ventilation of the cabinet to rack to avoid injury from a tip-over. allow proper cooling. Immediately stop using the component and have it inspected and/or serviced by a qualified service agency if: • The power supply cord or plug has been damaged • Objects have fallen or liquid has been spilled into the unit • The unit has been exposed to rain • The unit shows signs of improper operation • The unit has been dropped or damaged in any way
3 Figure 1: Controls and Connections Commandes et Branchements Bedienelemente und Anschlusse Controles y Conexiones De bedieningsorganen en aansluitingen Controlli e connessioni Kontroller och anslutningar e?„‡I? UO?‡‚IAIE? E ?‡A?AI? P V D Q S X T H N O X OFF ON PHONO CD TUNER AUX 1 X AUX 2 AUX 3 TAPE 1 TAPE 2 LISTENING MUTE X TUNING X T/P VOLUME 1 2 3 4 5 6 Figure 2: RR-AT97 Remote Control 7 8 9 Telecommande RR-AT97 X 0 10 +10 Fernbedienung RR-AT97 OFF ON Mando a Distancia RR-AT97 PHONO CD TUNER AUX 1 MEM MONO DIRECT BAND De afstandsbediening RR-AT97 X AUX 2 AUX 3 TAPE 1 TAPE 2 PTY TA TP DISPLAY Telecomando RR-AT97 LISTENING MUTE RR-AT97 fjarrkontroll X eUI?U RR-AT97 TUNING RANDOM X PHONO CD TUNER AUX 1 X AUX 2 AUX 3 TAPE 1 OFF T/P VOLUME 1 2 3 RECORDING 4 5 6 7 8 9 RR-AT97 0 10 +10 MEM MONO DIRECT BAND PTY TA TP DISPLAY RANDOM PHONO CD TUNER AUX 1 X AUX 2 AUX 3 TAPE 1 OFF RECORDING RR-AT97