На сайте 124169 инструкций общим размером 502.7 Гб , которые состоят из 6277380 страниц
Руководство пользователя ROTEL RC-1570. Основные функции, характеристики и условия эксплуатации изложены на 78 страницах документа в pdf формате.
Доступно к просмотру 78 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
RC-1570 POWER PHONES PHONO CD XLR TUNER AUX OPT COAX USB PC-USB MENU ENTER 5V 1A RC?1570 Stereo Control Amplifier Amplificateur de Controle Stereo Stereo-Vorverstarker Preamplificador Estereofonico Stereo-regelversterker Preamplificatore Stereo Stereokontrollforstarkare Предварительный стерео усилитель Owner’s Manual Manuel de l’utilisateur Bedienungsanleitung Manual de Instrucciones Gebruikershandleiding Manuale di istruzioni Instruktionsbok Инструкция пользователя
2 RC?1570 Stereo Control Amplifier Important Safety Instructions Notice WARNING: The rear panel power cord connector is the mains power disconnect device. The device must be located in an open area that The COMPUTER I/O connection should be handled by authorized allows access to the cord connector. persons only. The unit must be connected to a power supply only of the type and WARNING: There are no user serviceable parts inside. Refer all servicing voltage specified on the rear panel. (USA: 120 V/60Hz, EC: 230V/50Hz) to qualified service personnel. Connect the component to the power outlet only with the supplied WARNING: To reduce the risk of fire or electric shock, do not expose the power supply cable or an exact equivalent. Do not modify the supplied unit to moisture or water. Do not expose the unit to dripping or splashing. cable. A polarized plug has two blades, with one wider than the other. A Do not place objects filled with liquids, such as vases, on the unit. Do grounding plug has two blades plus a third grounding prong. These are not allow foreign objects to get into the enclosure. If the unit is exposed provided for your safety. Do not defeat grounding and/or polarization to moisture, or a foreign object gets into the enclosure, immediately safety provisions. If the supplied plug does not fit your outlet, please disconnect the power cord from the wall. Take the unit to a qualified consult an electrician for replacement of the obsolete outlet. Do not service person for inspection and necessary repairs. use extension cords. Read all the instructions before connecting or operating the component. The main plug of the power cordset is a disconnect device of the apparatus. In order to completely disconnect the apparatus from the supply mains, Keep this manual so you can refer to these safety instructions. the main plug of the power cordset should be unplugged from the mains Heed all warnings and safety information in these instructions and on (AC) outlet. The power LED indicator will not be lit up to show the power the product itself. Follow all operating instructions. cord is unplugged. The disconnect device shall remain readily operable. Clean the enclosure only with a dry cloth or a vacuum cleaner. Do not route the power cord where it will be crushed, pinched, bent, Do not use this unit near water. exposed to heat, or damaged in any way. Pay particular attention to the power cord at the plug and where the cord exits the back of the unit. Rotel products are designed to comply with international You must allow a minimum 10 cm or 4 inches of unobstructed directives on the Restriction of Hazardous Substances clearance around the unit. The power cord should be unplugged from the wall outlet during a (RoHS) in electrical and electronic equipment and the lightning storm or if the unit is to be left unused for a long period of time. disposal of Waste Electrical and Electronic Equipment (WEEE). The crossed wheelie bin symbol indicates Use only accessories specified by the manufacturer. compliance and that the products must be appropriately Use only with a cart, stand, rack, bracket or shelf system recycled or processed in accordance with these directives. RC-1570 recommended by Rotel. Use caution when moving the POWER unit in a stand or rack to avoid injury from a tip-over. PHONO CD XLR TUNER AUX OPT COAX USB PC-USB MENU ENTER PHONES 5V 1A Immediately stop using the component and have it inspected and/ This symbol means that this unit is double insulated. or serviced by a qualified service agency if: An earth connection is not required. • The power supply cord or plug has been damaged. • Objects have fallen or liquid has been spilled into the unit. • The unit has been exposed to rain. Pin Assignments • The unit shows signs of improper operation. Balanced Audio (3 pole XLR): • The unit has been dropped or damaged in any way. Pin 1: Ground / Screen 1 2 Pin 2: In phase / +ve / Hot The batteries in the remote control should not be exposed to excessive 3 Pin 3: Out of phase / -ve / Cold Do not place the unit on a bed, sofa, rug, or similar surface that could temperature such as sunshine, fire or other heat sources. block the ventilation openings. If the unit is placed in a bookcase or cabinet, there must be ventilation of the cabinet to allow proper cooling. Keep the component away from radiators, heat registers, stoves, or any other appliance that produces heat.
3 Figure 1: Controls and Connections Bedieningselementen en aansluitingen Commandes et Branchements Controlli e connessioni Bedienelemente und Anschlusse Kontroller och anslutningar Controles y Conexiones Органы управления и разъемы 1 2 3 4 RC-1570 POWER PHONO CD XLR TUNER AUX OPT COAX USB PC-USB MENU ENTER PHONES 5V 1A 5 6 7 8 9 0 - = q w e r t y u Figure 2: RR-AX92 Remote Control Telecommande infrarouge RR-AX92 ON Fernbedienung RR-AX92 MUTE VOLUME A OFF Mando a Distancia RR-AX92 - + B Afstandsbediening RR-AX92 BASS TREBLE BAL C Telecomando RR-AX92 K BYPASS MENU D RR-AX92 fjarrkontroll Пульт ДУ RR-AX92 ENT E DIM EXIT L F 1 2 3 4 5 6 G 7 8 9 0 >10 RND M H - TUNE + - PRESET + N SPKR A SPKR B RPT I PHONO TUNER CD BAL XLR USB PC-USB AUX 1 AUX 2 J COAX1 COAX2 OPT 1 OPT 2 RR-AX92