На сайте 124105 инструкций общим размером 502.41 Гб , которые состоят из 6273290 страниц
Руководство пользователя ARCAM DiVA CD93 (T). Основные функции, характеристики и условия эксплуатации изложены на 8 страницах документа в pdf формате.
Доступно к просмотру 8 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
H A N D B O O K CD93 Arcam CD93 Compact Disc player English Lecteur de Disque Compact Arcam CD93 Francais Arcam CD93 Compact Disc-Spieler Deutsch
Safety guidelines English CAUTION ATTENTION 8. Cleaning Unplug the unit from the mains supply before cleaning. RISK OF ELECTRIC RISQUE DE CHOC ELECTRIQUE SHOCK DO NOT OPEN NE PAS OUVRIR The case should normally only require a wipe with a soft, damp, lint-free cloth. Do not use paint thinners or other chemical CAUTION: To reduce the risk of electric shock, do not solvents for cleaning. remove cover (or back). No user serviceable parts inside. Refer servicing to qualified service personnel. We do not advise the use of furniture cleaning sprays or WARNING: To reduce the risk of fire or electric shock, polishes as they can cause indelible white marks if the unit is subsequently wiped with a damp cloth. do not expose this apparatus to rain or moisture. The lightning flash with an arrowhead symbol within an equilateral 9. Power sources triangle, is intended to alert the user to the presence of uninsulated Only connect the appliance to a power supply of the type ‘dangerous voltage’ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. described in the operating instructions or as marked on the The exclamation point within an equilateral triangle is intended to alert appliance. the user to the presence of important operating and maintenance 10. Power-cord protection (servicing) instructions in the literature accompanying the product. Power supply cords should be routed so that they are not likely CAUTION: In Canada and the USA, to prevent electric to be walked on or pinched by items placed upon or against shock, match the wide blade of the plug to the wide slot them, paying particular attention to cords and plugs, and the in the socket and insert the plug fully into the socket. point where they exit from the appliance. Important safety instructions 11. Grounding This product is designed and manufactured to meet strict Ensure that the grounding means of the appliance is not quality and safety standards. However, you should be aware of defeated. the following installation and operation precautions: 12. Power lines 1. Take heed of warnings and instructions Locate any outdoor antenna/aerial away from power lines. You should read all the safety and operating instructions 13. Non-use periods before operating this appliance. Retain this handbook for future If the unit has a standby function, a small amount of current will reference and adhere to all warnings in the handbook or on the continue to flow into the equipment in this mode. Unplug the appliance. power cord of the appliance from the outlet if left unused for a 2. Water and moisture long period of time. The presence of electricity near water can be dangerous. 14. Abnormal smell Do not use the appliance near water – for example next to a If an abnormal smell or smoke is detected from the appliance, bathtub, washbowl, kitchen sink, in a wet basement or near a turn the power off immediately and unplug the unit from the swimming pool, etc. wall outlet. Contact your dealer immediately. 3. Object or liquid entry 15. Servicing Take care that objects do not fall and liquids are not spilled into You should not attempt to service the appliance beyond that the enclosure through any openings. Liquid filled objects such described in this handbook. All other servicing should be as vases should not be placed on the equipment. referred to qualified service personnel. 4. Ventilation 16. Damage requiring service Do not place the equipment on a bed, sofa, rug or similar The appliance should be serviced by qualified service personnel soft surface, or in an enclosed bookcase or cabinet, since when: ventilation may be impeded. We recommend a minimum distance of 50mm (2 inches) around the sides and top of the A. the power-supply cord or the plug has been damaged, or appliance to provide adequate ventilation. B. objects have fallen, or liquid has spilled into the appliance, or 5. Heat C. the appliance has been exposed to rain, or Locate the appliance away from naked flames or heat D. the appliance does not appear to operate normally or producing equipment such as radiators, stoves or other exhibits a marked change in performance, or appliances (including other amplifiers) that produce heat. E. the appliance has been dropped or the enclosure damaged. 6. Climate The appliance has been designed for use in moderate Safety compliance climates. This product has been designed to meet the IEC 60065 7. Racks and stands international electrical safety standard. Only use a rack or stand that is recommended for use with audio equipment. If the equipment is on a portable rack it should be moved with great care, to avoid overturning the combination. CD93/92 CD93 CD93 22 3
Using this handbook English This handbook has been designed to give you all the information you need to install, connect, set up and use the Contents Arcam CD93 compact disc player. The CR-314 remote control Safety guidelines................................................... 2 handset supplied with this equipment is also described. Important safety instructions...................................2 Safety compliance .................................................2 Safety Using this handbook .............................................. 3 Safety guidelines are set out on the inside front cover of this Safety...................................................................3 handbook. Digital to Analogue conversion ................................3 Many of these items are common sense precautions, but for Installation ............................................................ 4 your own safety, and to ensure that you do not damage the Positioning the unit.................................................4 unit, we strongly recommend that you read them. Connecting to other equipment ...............................4 CD93 back panel (part) ..........................................4 Digital to Analogue conversion Connecting to a power supply.................................4 The CD93 incorporates the latest audio up-sampling technology Using your CD player............................................. 5 to convert the 44.1kHz data from the CD up to 192kHz in CDs with text.........................................................5 24-bit precision using the Analog Devices AD1896 sample rate Using the remote control ....................................... 6 converter. CR-314 Remote Control..........................................6 The 192kHz audio data is converted into the analogue domain using four Wolfson Micro WM8740 24-bit stereo DACs. Left and Technical specification .......................................... 7 right output channels are made using two stereo DAC chips Guarantee............................................................. 8 per channel, both operating in dual mono configuration. The On-line registration................................................ 8 resulting four mono signals (two for each channel) are summed together to help improve dynamic range, linearity and therefore distortion. Due to the higher sample rates, the digital filters roll off less aggressively than for standard DACs, and the analogue filters have a wider bandwidth resulting in less phase distortion, particularly for the higher frequencies. CD93 CD93 2 3