PROTECT YOUR Owner’s Manual 1 Completed and signed start-up forms MUST be submitted and approved INVESTMENT! by Tripp Lite to activate your warranty. SmartOnline 3-Phase UPS Systems ™ Models: SU20KX, SU40KX, SU60KX, SU80KX 2 3 Input/Output: 220/380V, 230/400V or 240/415V AC, 3O, 4-wire + ground Not suitable for mobile applications. 4 5 6 7 8 9 10 11 12 13 1111 W. 35th Street, Chicago, IL 60609 USA 14 www.tripplite.com/support Copyright © 2010 Tripp Lite. All trademarks are the sole property of their respective owners. 1
Table of Contents 1 1 Introduction 3 10 Display and Configuration 33 2 Important Safety Instructions 4 10-1 Control Panel Diagram 33 2 10-2 Display Hierarchy 33 3 Control Panel Features 6 10-3 Default Display 34 4 Front and Rear Panel Features 7 10-3-1 Status Display 34 5 Cabinet Installation 9 10-4 Main Menu 37 3 5-1 Preparation 9 10-5 UPS Setup 39 5-2 Unpacking 9 10-5-1 Bypass Setup 40 5-3 Placement 10 10-5-2 Output Setup 41 10-5-3 Battery Setup 43 4 6 Internal Battery Connection 11 10-5-4 Charger Setup 46 (Models SU20KX and SU40KX Only) 10-5-5 Parallel Setup 47 6-1 Internal Battery Wiring Diagrams 11 6-2 Internal Battery Connection Procedure 13 10-5-6 Control & Test Setup 48 10-5-7 Local Setup 50 5 7 Wiring 16 10-6 Maintenance 53 7-1 Wiring Warnings 16 7-2 Wiring Preparation 16 11 Communications 55 11-1 Communications Interfaces 55 7-3 UPS System Terminal Block Diagram 17 6 7-4 External Battery Cabinet Wiring Diagrams 17 11-2 SNMPWEBCARD Slot 55 7-5 Electrical and Cable Data 18 11-3 Input Dry Contact Interface 55 11-4 Remote Emergency Power Off (EPO) Circuit Diagram 56 7-6 External Battery Cabinet Wiring 19 7-7 AC Input/Output Wiring (Single UPS) 20 11-5 Auxiliary Dry Contact Input Circuit Diagram 56 7 7-8 AC Input/Output Wiring (Parallel UPS – Single Input) 21 11-6 External Battery Cabinet Temperature Inputs 56 7-9 AC Input/Output Wiring (Parallel UPS – Dual Inputs) 21 11-7 External Battery Status Input 56 11-8 Output Dry Contact Interface Detail 57 8 Operating Modes 22 11-9 Output Dry Contact Circuit Diagram 58 8-1 Online (Normal) Mode (Single UPS) 22 11-10 RS-232 Serial Port Circuit Diagram 58 8 8-2 Battery Backup Mode (Single UPS) 22 11-11 Parallel Configuration Port 58 8-3 Auto Bypass Mode (Single UPS) 22 8-4 Manual Bypass Mode (Single UPS) 22 12 Specifications 59 8-5 Online Mode (Parallel UPS) 23 12-1 UPS System Technical Specifications 59 9 8-6 Battery Backup Mode (Parallel UPS) 23 12-2 UPS System Floor Loading Table 59 12-3 Battery Pack Floor Loading Table 59 8-7 Auto Bypass Mode (Parallel UPS) 23 8-8 Manual Bypass Mode (Parallel UPS) 24 13 Storage and Service 60 8-9 Hot Standby Mode (Parallel UPS) 24 14 Warranty 60 10 9 Start-Up, Shutdown and Bypass 25 9-1 Control Panel and Breaker Diagrams 25 9-2 Preliminary Checklist (Single UPS) 25 11 9-3 Normal Start-Up Procedure (Single UPS) 25 9-4 Battery Start-Up Procedure (Single UPS) 26 9-5 Manual Bypass Procedure (Single UPS) 27 9-6 Shutdown Procedure (Single UPS) 27 12 9-7 Preliminary Checklist (Parallel UPS) 28 9-8 Start-Up Procedure (Parallel UPS) 29 9-9 Shutdown Procedure (Parallel UPS) 30 9-10 Manual Bypass Procedure (Parallel UPS) 31 13 9-11 Switching from Manual Bypass to Normal (Parallel UPS) 32 14 2
1 – Introduction 1 Tripp Lite’s SmartOnline 3-Phase UPS Systems (Models SU20KX, SU40KX, SU60KX and SU80KX) are ideal for backing up and protecting data centers, telecommunications (VoIP), networks, industrial facilities, security/emergency systems and more. Advanced Features: 2 • True on-line double conversion with superior IGBT inverter technology • Low input current THD allows 1:1 generator sizing for maximum efficiency and cost savings • Internal N+1 power module redundancy (SU40KX, SU60KX and SU80KX) 3 • Built-in parallel or hot standby redundancy (1+1) capability for increased capacity or fault-tolerance • Up to 80kVA capacity in a compact footprint; up to 160kVA in parallel configuration • High input power factor and high efficiency with low thermal loss and low noise • Simplified, easy-to-repair, long-life, high-availability system design 4 • Redundant auxiliary power and control circuits • Dual input design with separated rectifier and bypass input • All models support external battery cabinets for extended battery backup runtime 5 • High-resolution LCD status screen simplifies operation and delivers detailed operational information, including system block diagrams 6 7 8 9 10 11 12 13 14 3