На сайте 124169 инструкций общим размером 502.7 Гб , которые состоят из 6277380 страниц
Руководство пользователя TRIPP LITE SU100KX2. Основные функции, характеристики и условия эксплуатации изложены на 232 страницах документа в pdf формате.
Доступно к просмотру 232 страницы. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
YOUR INVESTMENT! Owner’s Manual 1 Completed and signed start-up forms PROTECT MUST be submitted and approved by Tripp Lite to activate your warranty. 2 SmartOnline 3-Phase UPS Systems ™ Model: SU120KX2 3 Input/Output: 220/380V, 230/400V or 240/415V AC, 3O, 4-wire + ground Not suitable for mobile applications. 4 5 6 7 8 9 10 11 12 13 1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support 14 Copyright © 2012 Tripp Lite. All trademarks are the sole property of their respective owners. 1 12-212-93-3141.indb 1 12/28/2012 11:16:51 AM
Table of Contents 1 1 Introduction 3 9 Power Module Status and Replacement 29 2 Important Safety Instructions 4 9-1 Power Module Features and Status 29 2 9-2 Preliminary Replacement Checklist 29 3 Control Panel Features 6 9-3 Replacement Procedure 29 4 Front and Rear Panel Features 7 10 Display and Configuration 30 5 Cabinet Installation 9 10-1 Control Panel Diagram 30 3 5-1 Preparation 9 10-2 Display Hierarchy 30 5-2 Unpacking 9 10-3 Default Display 31 5-3 Placement 10 10-3-1 Status Display 31 4 6 Wiring 11 10-4 Main Menu 34 6-1 Wiring Warnings 11 10-5 UPS Setup 36 6-2 Wiring Preparation 11 10-5-1 Bypass Setup 37 6-3 UPS System Terminal Block Diagram 12 10-5-2 Output Setup 38 5 6-4 External Battery Cabinet Wiring Diagrams 12 10-5-3 Battery Setup 40 6-5 Electrical and Cable Data 13 10-5-4 Charger Setup 43 6-6 External Battery Cabinet Wiring 14 10-5-5 Parallel Setup 44 6-7 AC Input/Output Wiring (Single UPS—SUS) 14 10-5-6 Control & Test Setup 45 6 6-8 AC Input/Output Wiring (Parallel Configuration—2x MUS) 15 10-5-7 Local Setup 47 6-9 AC Input/Output Wiring (Parallel Configuration—4x MUS) 16 10-6 Maintenance 50 7 Operating Modes 17 11 Communications 52 7-1 Online (Normal) Mode (Single UPS—SUS) 17 11-1 Communications Interfaces 52 7 7-2 Battery Backup Mode (Single UPS—SUS) 17 11-2 SNMPWEBCARD Slot 52 7-3 Auto Bypass Mode (Single UPS—SUS) 17 11-3 Input Dry Contact Interface 52 11-4 Remote Emergency Power Off (EPO) Circuit Diagram 53 7-4 Manual Bypass Mode (Single UPS—SUS) 17 7-5 On-line (Normal) Mode (Parallel UPS—MUS) 18 11-5 Auxiliary Dry Contact Input Circuit Diagram 53 8 7-6 Battery Backup Mode (Parallel UPS—MUS) 18 11-6 External Battery Cabinet Temperature Inputs 53 11-7 External Battery Status Input 53 7-7 Auto Bypass Mode (Parallel UPS—MUS) 18 7-8 Manual Bypass Mode (Parallel UPS—MUS) 19 11-8 Output Dry Contact Interface Detail 54 7-9 External Maintenance Bypass (Parallel UPS—MUS) 19 11-9 Output Dry Contact Circuit Diagram 55 9 8 Start-Up, Shutdown and Bypass 20 11-10 RS-232 Serial Port Circuit Diagram 55 8-1 Control Panel and Breaker Diagrams 20 11-11 Parallel Configuration Port 55 8-2 Preliminary Checklist (Single UPS—SUS) 20 12 Specifications 56 12-1 UPS System Technical Specifications 56 10 8-3 Standard Start-Up Procedure (Single UPS—SUS) 21 12-2 UPS System Floor Loading Table 56 8-4 Battery Start-Up Procedure (Single UPS—SUS) 22 8-5 Manual Bypass Procedure (Single UPS—SUS) 22 13 Storage and Service 57 8-6 Shutdown Procedure (Single UPS—SUS) 24 14 Warranty 58 11 8-7 Preliminary Checklist (Parallel UPS—MUS) 24 8-8 Start-Up Procedure (Parallel UPS—MUS) 25 Espanol 59 8-9 Shutdown Procedure (Parallel UPS—MUS) 26 8-10 Switching to Manual Bypass Mode from Normal Mode Francais 117 (Parallel UPS—MUS) 27 12 8-11 Switching to Normal Mode from Manual Bypass Mode Русский 175 (Parallel UPS—MUS) 28 13 14 2 12-212-93-3141.indb 2 12/28/2012 11:16:51 AM
1 – Introduction 1 Tripp Lite’s SmartOnline 3-Phase KX2-Series UPS System (Model SU120KX2) is ideal for backing up and protecting data centers, telecommunications (VoIP), networks, industrial facilities, security/emergency systems and more. Advanced Features: 2 • True on-line double conversion with superior IGBT inverter technology • Low input current THDi allows 1:1 generator sizing for maximum efficiency and cost savings • Internal N+1 power module redundancy 3 • Built-in parallel or hot standby redundancy capability for increased capacity or fault-tolerance • Up to 120kVA capacity in compact footprint; up to 480kVA in parallel capacity configuration with 4 units • High input power factor and high efficiency with low thermal loss and low noise • Simplified, easy-to-repair, long-life, high-availability system design 4 • Redundant auxiliary power and control circuits within each power module and at the system level • Single feed input design • Supports external battery cabinets for extended battery backup runtime 5 • High-resolution LCD status screen simplifies operation and delivers detailed operational information, including system block diagrams 6 7 8 9 10 11 12 13 14 3 12-212-93-3141.indb 3 12/28/2012 11:16:51 AM