Руководство пользователя TRIPP LITE SMX5000XLRT3U. Основные функции, характеристики и условия эксплуатации изложены на 48 страницах документа в pdf формате.
Доступно к просмотру 48 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
200807051 93-2460 Smart 3U 230V OM.qxd 8/8/2008 10:10 AM Page 1 Owner’s Manual SmartPro 3U Rackmount ® (5000VA) Intelligent, Line-Interactive UPS Systems • 230V Input/Output • Extended-Run Options Not suitable for mobile applications. Important Safety Instructions 2 Mounting 3 Quick Installation 4 Optional Installation 5 Basic Operation 7 Storage and Service 11 Battery Replacement 12 Espanol 13 Francais 25 Ponneee 37 1111 W. 35th Street, Chicago, IL 60609 USA Customer Support: +1.773.869.1234 • www.tripplite.com ® Copyright ©2008 Tripp Lite. All rights reserved. SmartPro is a registered trademark of Tripp Lite.
200807051 93-2460 Smart 3U 230V OM.qxd 8/8/2008 10:10 AM Page 2 Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty. UPS Location Warnings • Use caution when lifting your UPS. Because of the considerable weight of all rackmount UPS systems, at least two people should assist in lifting and installing them. • Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight. • For best performance, the ambient temperature near your UPS should be between 0° C and 40° C (between 32° F and 104° F). • Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents or fan openings. • Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit's internal cooling, eventually causing product damage not covered under warranty. UPS Connection Warnings • The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply. Equipment Connection Warnings • Use of this equipment in life support applications where failure of this equipment can reason- ably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. • Do not connect surge suppressors or extension cords to the output of your UPS. This might overload the UPS and will void the surge suppressor and UPS warranties. Battery Warnings • Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should be performed only by authorized service personnel using the same number and type of batteries (sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal requirements. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at www.tripplite.com to locate the specific replacement battery for your UPS. • During hot-swap battery replacement, the UPS will not provide backup power in the event of a blackout or other power interruptions. • Do not operate UPS without batteries. • When adding external battery packs connect only Tripp Lite-recommended battery packs of the correct voltage and type. Do not connect or disconnect battery packs when the UPS is operating on battery power. 2
200807051 93-2460 Smart 3U 230V OM.qxd 8/8/2008 10:10 AM Page 3 Mounting Mount your equipment in either a 4-post or 2-post rack or rack enclosure. The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suit- able for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications. 4-Post Rack Mounting C C 1 Loosen the wingnuts A on each of the two adjustable side supports B ; adjust the length of the supports to match the depth of your rack; tighten wingnuts. Mount A A both side supports in the lowest space of your rack on C C B B the inside surfaces of the rails with user-supplied #10- 1 32 rack bolts and washers C . Note: Both support ledges should face inward. The side supports’ front and back holes are threaded and do not require nuts to E secure rack bolts. 2 Attach mounting ears D to the front mounting holes of your UPS E using the screws provided F . The ears should face forward. D F 2 G 3 Using an assistant if necessary, lift your UPS and slide it onto the mounting shelves (if your model includes the shelves). Attach your UPS to the rack by using the appropriate hardware G through its mounting ears and into the rack rails. 3 2-Post Rack (Telecom) Mounting If you mount 3U UPS models in 2-post racks, they require the addition of a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTRMKITWM, sold separately). See Installation Kit owner’s manual for installation procedure for 3U UPS models. Tower Mounting If you tower mount this UPS, it requires the addition of a Tripp Lite 2U to 9U tower stand (model: 2-9USTAND, sold separately). See owner's manual for installation procedure. Rotate the power module’s Control Panel to view it easier while the UPS is tower mounted. Insert a small screwdriver, or other tool, in the slots on either side of the Control Panel. Pop the panel out; rotate it; and pop the panel back into place. 3