WARRANTY User’s Guide REGISTRATION: chance to win a FREE Tripp Lite register online today for a product—www.tripplite.com/warranty SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A Table of Contents 1. Introduction 2 4. Telnet/SSH Console 26 4.3 Network Configuration 69 1.1 System Requirements 2 4.1 Device Menu 27 4.3.1 IP Configuration 69 4.1.1 Status 28 2. Installation and Configuration 2 4.1.2 Identification 29 4.3.1.1 Host Name 70 2.1 Saving Configuration Changes 2 4.1.3 Controls 30 4.3.1.2 Domain Data Entry Menu 70 2.2 Default UPS System 4.1.3.1 Control Data 31 4.3.1.3 IPV4 Settings 70 Shutdown Settings 2 4.1.4 Events 32 4.3.1.4 IPV6 Settings 71 2.3 Other Default Settings 3 4.3.1.5 DNS Settings 72 2.4 SNMP Configuration 3 4.1.5 Loads 35 4.1.5.1 Load Configuration 35 4.3.2 Remote Services 73 3. Web Console 4 4.1.5.2 Load Groups 36 4.3.2.1 Email Settings 73 3.1 Opening the Web Console 4 4.3.2.2 Remote Syslog 75 3.1.1 Alternate to Web Launch 4 4.1.5.3 Ramp/Shed Settings 37 4.3.2.3 Watchdog Settings 78 3.2 Web Console Interface 5 4.1.6 Preferences and Thresholds 38 4.3.3 User Interfaces 79 3.3 Device Summary 5 4.1.7 Device Alarms 39 3.4 Status Menu 5 4.1.8 Logs 39 4.3.3.1 Telnet/SSH 79 3.4.1 Status > Overview 5 4.2 System Configuration 39 4.3.3.2 Web Console 79 3.4.2 Status > Details 6 4.2.1 Address Book 39 4.3.3.3 SNMP Settings 80 3.4.3 Status > Alarms 7 4.2.1.1 Email Contacts 40 4.3.3.4 FTP 80 3.5 Device Menu 7 4.2.1.2 SNMP Contacts 41 4.3.3.5 Remote View Access Port 80 3.5.1 Device > Controls 7 4.2.1.3 HTTP Contacts 42 4.4 Alarms and Logging 81 3.5.2 Device > Loads 8 4.4.1 Alarms 81 3.5.3 Device > Load Groups 8 4.2.2 Global Actions 43 4.4.1.1 Alarm Details 82 3.5.4 Device > Events 9 4.2.2.1 Action Profiles 43 3.5.5 Device > Device Discovery 9 4.2.2.2 Schedules 55 4.4.2 View Logs 82 3.6 Actions Menu 10 4.2.3 Security 59 4.4.2.1 Data Log 83 3.6.1 Actions 10 4.2.3.1 Authentication Method 59 4.4.2.2 Event Log 85 3.6.1.1 Actions > Event Actions > 4.2.3.2 Local Users 60 4.4.3 Logging Settings 88 Device Actions 10 4.2.3.3 RADIUS Servers 63 4.4.3.1 Accounting Log Settings 88 3.6.1.2 Actions > Event Actions > 4.2.3.4 Change Password 64 4.4.3.2 Application Log Settings 88 General Actions 13 3.6.2 Actions > Scheduling 14 4.2.4 Date/Time 64 4.4.3.3 Data Log Settings 89 3.6.3 Actions > Address Book 15 4.2.4.1 Time Source Data 4.4.3.4 Event Log Settings 90 3.7 Logs 15 Entry Menu 64 4.4.3.5 Format Settings 91 3.7.1 Logs > Event Logs 15 4.2.4.2 Time Settings 65 4.5 About 92 3.7.2 Logs > Data 15 4.2.4.3 SNTP Settings 66 5. Command Line Interface 93 3.8 Preferences 16 4.2.4.4 RTC Settings 66 5.1 Syntax Conventions 93 3.8.1 Preferences > Network 16 4.2.5 Local Device Discovery 67 5.2 Manual Pages 94 3.8.2 Preferences > DNS 18 5.3 Output Conventions 94 3.8.3 Preferences > Security 18 4.2.6 Restart PowerAlert 68 5.4 Getting Started with the PowerAlert CLI 94 3.8.4 Preferences > System 22 3.8.5 Preferences > Restart 24 6. Troubleshooting 96 3.9 RSS Support 24 7. Technical Support 96 3.10 Help 25 8. Appendix 97 Documentation Notice: This User’s Guide is a supplement to the printed manual that came with your SNMPWEBCARD or network-enabled Tripp Lite device. Refer to the printed manual for instructions on hardware installation and basic configuration, including IP address assignment. If you have misplaced your printed manual, refer to the electronic version included on the bundled CD-ROM or download it at www.tripplite.com/support/manuals/. 1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support Copyright © 2013 Tripp Lite. All trademarks are the sole property of their respective owners.
1. Introduction SNMPWEBCARD is an optional network card that you can install in the accessory slot of a compatible UPS system, PDU* or cooling unit. SNMPWEBCARD connects your Tripp Lite device to your Ethernet network as a manageable device that supports remote monitoring, remote control and remote condition reporting. You can manage the device from PowerAlert Network Management System, an SNMP Network Management Station, a Web browser or telnet. Remote access capability allows you to reboot, control outlets, shed nonessential loads, monitor load levels and more. The SNMPWEBCARD can also send SNMP traps or email messages to the addresses you specify, alerting you automatically to events such as power failures. * SNMPWEBCARD is preinstalled in Tripp Lite Monitored and Switched PDUs, which can be identified by the presence of “MN” or “NET” in the model name. SNMPWECARD is also preinstalled in SRCOOLNET. 1.1 System Requirements • Tripp Lite UPS system, PDU, or cooling unit with compatible accessory slot or preinstalled SNMPWEBCARD. • Ethernet network that supports the TCP/IP protocol. Firewall ports 3664 and 3665 must be open. • One of the following options for remote monitoring and control: • PowerAlert Network Management System ® ® • SNMP-based Network Management Station (such as HP OpenView ) • Web browser that supports frames, forms and Java™ (such as Microsoft Internet Explorer 8.0 or later) (if launching vid browser) ® ® • VT-100 Telnet and/or SSH Client • For “Terminal Mode” configuration only: • Terminal emulation software program (such as TeraTerm Pro by Ayera Technologies) • Computer with available DB9 serial port Warning: Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. 2. Installation and Configuration For instructions on hardware installation and basic configuration, refer to the printed manual that came with your SNMPWEBCARD or Tripp Lite device. For instructions on loading a firmware or device driver upgrade on the SNMPWEBCARD, refer to the PowerAlert software release notes. The manual and release notes can be found on the bundled CD-ROM or downloaded from www.tripplite.com/manuals/. 2.1 Saving Configuration Changes While using PowerAlert, most of your configuration changes will take effect immediately so you can try out your configuration before committing to it. The Web and Telnet Menu user interfaces will typically advise you if your configuration requires a restart to take effect. In general, the configuration is not persisted permanently until you restart PowerAlert (or ‘reboot’ the SNMPWEBCARD). You should restart PowerAlert when your configuration is complete and before testing configurations that simulate or nearly simulate a power outage. For your convenience, most changes will auto-save after about 30 minutes of idle time. Changes to the network settings will not. Restarting PowerAlert cannot cause equipment powered through your UPS or PDU to experience an outage and has no effect on the general operation of your Tripp Lite device. 2.2 Default UPS System Shutdown Settings A When used with a Tripp Lite UPS, during a power failure, SNMPWEBCARD is pre-configured to shut down the UPS system two minutes after receiving a low battery signal. This allows the UPS system to provide B the maximum available runtime to connected equipment. If you want to change the default setting, follow these instructions and refer to Figure 2-1 and Figure 2-2: 1. Use a Web browser to open the PowerAlert console window for your E SNMPWEBCARD (see 3.1 Opening the Web Console for instructions). F 2. Click the Actions menu A and access the Event Actions submenu B . C 3. Select Device Shutdown in the Device Shutdown Actions C section. 4. Click the button on the bottom of the screen D to add a new action. D J 5. In the Name field E , type a name for the new action. Figure 2-1: UPS System Shutdown Settings 2
2. Installation and Configuration continued 6. Click the Action field F to access its submenu. Select the device to shut down in the Select Trigger Device section G . 7. Set how long the delay should be before the action will take place H . 8. Select the Event(s) that will trigger the action I . 9. Click the button on the bottom of the screen J . G H I Note: Whenever changes are made, the button must be pressed to submit the changes before moving off of the page. This also includes deleting fields using the button. After selecting an item and clicking the button press the button to commit the change. Figure 2-2: UPS System Shutdown Settings 2.3 Other Default Settings Setting Default Value Additional Information IP address Obtain from DHCP Section 3.8.1 Telnet Access Enabled Section 3.8.1 SSH Access Enabled Section 3.8.1 HTTP Access Enabled Section 3.8.1 HTTP Access Enabled Section 3.8.1 SNMPv1 Access Enabled—Read-Only Community—public Section 3.8.2 SNMPv2 Access Enabled—Read-Write Community—tripplite Section 3.8.2 SNMPv3 Access Enabled Section 3.8.2 localadmin localmanager localguest See table below Default users and passwords localadmin/localadmin Section 3.8.2 localmanager/localmanger localguest/localguest Radius Disabled Section 3.8.2 Email Notification Default email action profile setup to trigger 30 seconds after an alarm. Add email destinations to Section 3.6 the address book. SNMP Trap Notification Default SNMP Trap action profile setup to trigger 30 seconds after an alarm. Add trap destinations Section 3.6 to the address book. Event Logging Enabled Section 3.7 Data Logging Enabled Section 3.7 2.4 SNMP Configuration SNMPWEBCARD allows a compatible Tripp Lite device to function as an SNMP-managed device on your network, using the SNMP agent and Management Information Base (MIB). The SNMP agent resides in the SNMPWEBCARD firmware and responds to standard SNMP commands (Get, Get Next and Set). It can also generate SNMP traps (messages). The MIB determines which parameters can be monitored and controlled. Two MIB files—Tripplite.mib and RFC1628.mib—must be loaded on each Network Management Station that will monitor the managed device. (The files are provided on the CD-ROM included with the SNMPWEBCARD or network-enabled Tripp Lite device. Consult your Network Management Station software documentation for instructions on how to import MIB files.) SNMPv3 Definitions User Name The identifier of the user profile. SNMP version 3 maps Gets, Sets and Traps to a user profile by matching the user name of the profile to the user name in the data packet being transmitted. A user name can have up to 32 ASCII characters. Authentication Passphrase A phrase of 8 to 32 ASCII characters that verifies that the Network Management System (NMS) communicating with this device through SNMPv3 is the NMS it claims to be, that the message has not been changed during transmission, and that the message was communicated in a timely manner, indicating that it was not delayed and that it was not copied and sent again later at an inappropriate time. Privacy Passphrase A phrase of 8 to 32 ASCII characters that ensures the privacy of the data (by means of encryption) that a Network Management System (NMS) is sending to this device or receiving from this device through SNMPv3. Authentication Protocol The Tripp Lite implementation of SNMPv3 supports only MD5 authentication. Privacy Protocol The Tripp Lite implementation of SNMPv3 supports only DES as the protocol for encrypting and decrypting data. Public Value A field provided to enter a username/password hint for SNMPv3 Admin users. This SNMPv3 value is part of the SNMPv3 USM User Table. 3