Owner’s Manual 3-Phase Metered Power Distribution Units PDU3MV6L2120 PDU3MV6L2130 PDU3XMV6G20 (Series Number: AGPD8414) (Series Number: AGPD8415) (Series Number: AGPD8420) PDU3MV6L2120LV PDU3MV6H50 PDU3XMV6L2220 (Series Number: AGPD8414) (Series Number: AGPD8416) (Series Number: AGPD8420) PDU3MV6L2120B PDU3MV6H50A PDU3MV6L2130A (Series Number: AGPD8414) (Series Number: AGPD8417) (Series Number: AG-00E3) Important Safety Insructions 2 Installation 3 Digital Load Meter 6 Features 7 Service 8 Warranty and Product Registration 9 Espanol 10 Francais 19 ??????? 28 1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support Copyright © 2015 Tripp Lite. All rights reserved. 1 15-07-049-933145.indb 1 8/7/2015 1:58:11 PM
Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation, operation, and storage of this product. Failure to heed these instructions and warnings may affect the product warranty. • The PDU provides convenient multiple outlets, but it DOES NOT provide surge or line noise protection for connected equipment. • The PDU is designed for indoor use only in a controlled environment away from excess moisture, temperature extremes, conductive contaminants, dust or direct sunlight. • Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to ground. • The power requirement for each piece of equipment connected to the PDU must not exceed the individual outlet’s load rating. • The total power requirement for equipment connected to the PDU must not exceed the maximum load rating for the PDU. • Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable parts inside. • Do not attempt to modify the PDU, including the input plugs and power cables. • Do not attempt to use the PDU if any part of it becomes damaged. • Do not attempt to mount the PDU to an insecure or unstable surface. • Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. • Never attempt to install electrical equipment during a thunderstorm. • Keep indoor ambient temperature between 32°F and 104°F (0°C and 40°C). • Connect the PDU to an outlet that is in accordance with your local building codes and that is adequately protected against excess currents, short circuits and earth faults. • Do not attempt to open the PDU; there are no user-serviceable parts inside. • The PDU must be installed by a qualified technician only. • Install in accordance with National Electrical Codes. Be sure to use the proper over current protection for the installation, in accordance with the plug rating/equipment rating. • The electrical sockets supplying power to the equipment shall be installed near the equipment and be easily accessible. 2 15-07-049-933145.indb 2 8/7/2015 1:58:11 PM
Installation Mounting the PDU Note: The illustrations may differ somewhat from your PDU model. Regardless of configuration, the user must determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting configurations may vary. Screws for attaching the mounting brackets and cord retention shelf to the PDU are included. Use only the screws supplied by Tripp Lite, or their exact equivalent. 1-1 Attach the mounting 1-2 (Optional) Attach the 1-3 For toolless mounting, brackets to the PDU. cord retention position the PDU as bracket(s) to the PDU. desired in the rack enclosure, align the buttons with the rack mounting slots, and slide the PDU into position. 1-1 1-2 1-3 1-4 To install the PDU with its outlets facing B the rear of the rack, use the included A PDUMVROTATEBRKT accessory. First, attach the mounting button A to the V-shaped bracket B using the included screw and washer. Then, use the button-mount slot to attach the bracket to the PDU and the mounting button to attach the PDU to the rack. The bracket effectively repositions the mounting brackets, allowing for the PDU outlets to face the rear of the rack. 1-4 1-5 If your PDU cannot be mounted using the toolless mounting option, the mounting brackets can be used. Attach the PDU to a vertical rail in your rack or rack enclosure. (Use the mounting hardware that came with your rack or rack enclosure to attach the mounting brackets to the rail.) 1-5 3 15-07-049-933145.indb 3 8/7/2015 1:58:13 PM