Owner’s Manual SMX & OMNIX Medical Grade UPS Systems Models: OMNIX350HG SMX700HG SMX1200XLHG (Series Number: AGOM6832) (Series Number: AGSM6833) (Series Number: AGSM6834) Not suitable for mobile applications. Important Safety Instructions 2 Package Contents 5 Quick Installation 6 Basic Operation 8 Guidance and Manufacturer’s Declaration 14 Storage & Service 15 Warranty Registration 16 Espanol 17 Francais 33 Deutsch 49 1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support Copyright © 2014 Tripp Lite. All rights reserved. 1 14-03-279-93328F.indb 1 4/24/2014 3:19:13 PM
Important Safety Instructions Statement of Intended Use Tripp Lite Medical-Grade UPS Systems are intended to support and protect non-medical computer equipment and medical devices that require leakage current reduction, surge protection, voltage regulation, line noise filtering and battery backup during power outages and generator testing, both inside and outside patient care areas. Tripp Lite’s Medical-Grade UPS Systems come with hospital- grade plugs and receptacles that reduce leakage to below 100?A. Product Information OMNIX350HG SMX700HG SMX1200XLHG AC Input Voltage 230V 230V 230V Input Amp(s) 1.78A 4 5 Output Amps (s) 1.5 2 3.3 Rated Power (VA/Watts) 350VA, 225W 700VA, 450W 1000VA, 750W Frequency 50/60 Hz 50/60 Hz 50/60 Hz No. of Phases Single Single Single Class Type Class I Class I Class I Plug/Connector Type Inlet C14 with dongle Inlet C14 with dongle Inlet C14 with dongle Operation Continuous Continuous Continuous AC Input Protection (Qty,/type/rating) Input breaker (2 x 3A) Input breaker (2 x 5A) Input breaker (2 x 6A) thermal thermal thermal Max Leakage Current (uA) Less than 100uA Less than 100uA Less than 100uA Weight 11.5 kg 19.1 kg 20.6 kg Known Contraindication None None None SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty. Note: Your UPS incorporates fusing only in the ungrounded phase conductor. UL 60601-1 certified UPS systems must not be used in countries other than the United States and Canada and must be used only in healthcare facilities on grounded systems where conditions of maintenance and supervision ensure that only qualified persons will service the electrical distribution system. UPS Location Warnings Relevant Symbols Denotes that information in the manual should be reviewed before use. Used to signal as a warning that a statement is particularly important and could pose a safety risk. Warning-Dangerous Voltage No sitting Denotes general warning sign No stepping on surface Refer to Instruction Manual/Booklet No pushing 2 14-03-279-93328F.indb 2 4/24/2014 3:19:13 PM
Important Safety Instructions continued • Do not use this equipment within oxygen-enriched atmospheres, or within 0.3 m of a point at which an oxygen-enriched atmosphere is intentionally vented. • Use caution when lifting UPS. Because of the considerable weight of all UPS systems, at least two people should assist in lifting and installing them. • Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight. • For best performance, the UPS should be used in a location that meets the following conditions: Temperature: 0 to 40° C; Humidity: 0 to 95% (non-condensing); Elevation: <2,000 m above sea level; Pressure: >95kPa • Leave adequate space around all sides of the UPS for proper ventilation. Do not obstruct its vents or fan openings. • Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered under warranty. UPS Connection Warnings • The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply. • Connect your UPS to a properly grounded AC power outlet. Do not modify the UPS’s plug in a way that would eliminate the UPS’s connection to ground. Do not use adapters that eliminate the UPS’s connection to ground. • Do not plug your UPS into itself; this will damage the UPS and void your warranty. • If you are connecting your UPS to a motor-powered AC generator, the generator must provide filtered, frequency-regulated computer-grade output. Connecting your UPS to a generator will void its Ultimate Lifetime Insurance. • To remove the UPS from the supply mains, the appliance inlet serves as a disconnect device. • Once connected, do not limit access to the input plug. The plug must be accessible to be used as a means of disconnection. CAUTION: Do not remove cover for 5 minutes after disconnecting all sources of supply. Risk of electric shock—hazardous live parts inside. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. This UPS receives power from more DC sources; disconnection of the AC and DC source is required to de-energize the unit before servicing. CAUTION: To ensure proper grounding, the input cord must remain connected to the supply mains at all times during use. CAUTION: Do not exceed total rated output WARNING: No modification of this equipment is allowed. WARNING: To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. 3 14-03-279-93328F.indb 3 4/24/2014 3:19:13 PM