Owner’s Manual Models: OMNIVSINT800, OMNIVSINT1000, OMNIVSINT1500XL* 230V Input, Line-Interactive UPS Systems (Tower Configuration) * Extended runtime options Not suitable for mobile applications. Important Safety Instructions 2 Quick Installation 3 Basic Operation 5 Storage & Service 8 Espanol 9 Francais 17 ??????? 25 1111 W. 35th Street Chicago, IL 60609 USA www.tripplite.com/support Copyright © 2009 Tripp Lite. All rights reserved. 1 200908153 93-2205.indd 1 11/2/2009 1:17:15 PM
Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty. UPS Location Warnings • Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight. • For best performance, keep the indoor temperature between between 32? F and 104? F (0? C and 40? C). • Leave adequate space around all sides of the UPS for proper ventilation. UPS Connection Warnings • Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS. • Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground connection. • Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet. • If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. Equipment Connection Warnings • Use of this equipment in life support applications where failure of this equipment can rea- sonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. • Do not connect surge suppressors or extension cords to the output of your UPS. Battery Warnings • Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should be per- formed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal requirements. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/ index.cfm to locate the specific replacement battery for your UPS. 2 200908153 93-2205.indd 2 11/2/2009 1:17:15 PM
Quick Installation 1 Unplug the computer’s power cord from both AC outlet and the computer’s AC input. 1 IEC320-C14 plug shown 2 Insert the female plug of the NORM DELAY computer’s cord into the UPS’s AC input. Insert the A male plug of the computer's A cord into AC outlet. NOTE! After you plug the UPS into a live AC outlet, the UPS will turn ON automatically. See “ON/OFF” Button description in the 2 Basic Operation section if you want to place the UPS in any mode other than ON. Shown: OMNIVSINT1000 3 Using one of the jumper cords supplied with the UPS, insert NORM DELAY the cord’s female plug into computer’s AC input B . Insert the cord’s male plug into any of UPS’s female output receptacles. B 3 Shown: OMNIVSINT1000 NORM DELAY 4 Plug additional equipment into the UPS.* Use one of the additional jumper cords supplied with the UPS, or order additional jumper cords from Tripp Lite. Log on to www.tripplite.com/support; order part # P004-006. * Your UPS is designed to support only computer equipment. You will overload the UPS if the total VA ratings for all the equipment you 4 connect exceeds the UPS’s output capacity (see Specifications). To Shown: OMNIVSINT1000 find your equipment's VA ratings, look on their nameplates. If the equipment is listed in amps, multiply the number of amps by 230 to determine VA. (Example: 1 amp ? 230 = 230 VA). If you are unsure if you have overloaded the UPS’s outlets, see “OUTPUT LOAD LEVEL” LED description. 3 200908153 93-2205.indd 3 11/2/2009 1:17:16 PM