Owner’s Manual Automatic Voltage Switch Model: AVS5D Introduction The AVS5D is a 5 amp rated automatic voltage switch that protects appliances from high voltages, low voltages (including brownouts), power surges, spikes and lighting. It does this by switching off connected equipment if the power flowing to it goes outside preset limits, and will reconnect automatically when power returns to normal (except in the case of an overload condition). There will be a delay before the reconnection to ensure power stability. 1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support Copyright © 2014 Tripp Lite. All rights reserved. 1 14-01-269-933302.indd 1 2/6/2014 2:33:58 PM
Product Overview 7 6 5 3 4 1 2 1 BS 1363 Plug Connects to wall outlet. 2 BS 1363 Outlet Connects to appliance plug. 3 F1 & F2 Program Buttons Using the two buttons, you can set the output 4 over/under voltage, overload protection value, browse settable parameters and change digital display mode. During normal operation, you can press F2 to display the load. After 3 seconds, the switch returns to the voltage display. 5 Voltage LED Illuminates when the digital display shows voltage. 6 Load LED Illuminates when the digital display shows the load in watts. 2 14-01-269-933302.indd 2 2/6/2014 2:33:58 PM
Product Overview 7 Digital Display Shows voltage, wattage, status and settings. A) U-H Output Overvoltage Protection Status When output voltage exceeds the preset limit and doesn’t return to within the preset limits after 1 second, your equipment will be disconnected by the switch. U-H will flash on the display every .5 seconds as long as the overvoltage condition exists. B) U-L Output Undervoltage Protection Status When output voltage goes lower than the preset limit and doesn’t return to within the preset limits after 1 second, your equipment will be disconnected by the switch. U-L will flash on the display every .5 seconds as long as the undervoltage condition exists. C) P-H Overload Protection Status When the load exceeds the preset range (nominally 110-120%) and lasts longer than 6 seconds (within this 6 seconds no action will be taken by the AVS5D), the switch will disconnect from power. P-H will flash on the display every .5 seconds as long as the overload condition exists. When the load exceeds the preset range (nominally 150%) and lasts longer than 1 second, the switch will disconnect from power. P-H will flash on the display every .5 seconds as long as the overload condition exists. Overload Faults - You must power cycle the unit to restore the current flow. The unit does not reset automatically from this type of fault. D) Start Up Delay When first powered up, the unit will count down a set number of seconds (default is 6) before monitoring voltage. E) Parameter Setting Codes E-0 Delay setting E-1 Undervoltage protection value setting E-2 Overvoltage protection value setting E-3 Overload protection value setting E-4 Displays output voltage or loading power value after startup (U= voltage, P= watts) E-5 Restores default settings Note: The code and value flash alternately every second while changing settings. 3 14-01-269-933302.indd 3 2/6/2014 2:33:58 PM