Руководство пользователя TRIPP LITE AVRX750U. Основные функции, характеристики и условия эксплуатации изложены на 18 страницах документа в pdf формате.
Доступно к просмотру 18 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Owner’s Manual AVRX550U & AVRX750U UPS Systems Not suitable for mobile applications. Important Saftey Instructions 2 Features 3 Installation 4 Optional Installation 5 Troubleshooting 5 Storage & Service 6 Espanol 7 Francais 13 1111 W. 35th Street • Chicago, IL 60609 USA www.tripplite.com/support Copyright © 2010 Tripp Lite. All rights reserved. 1
Important Safety Instructions SAVE THESE INSTRUCTIONS—This manual contains instructions and warnings that should be followed during the installation, operation and storage of Tripp Lite UPS Systems. Failure to heed these warnings may affect your warranty. UPS Location Warnings • Install UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight. • Keep the indoor temperature between 32? F and 104? F (0? C and 40? C). • Leave adequate space around all sides of UPS for proper ventilation. UPS Connection Warnings • Connect UPS directly to a properly grounded AC power outlet. Do not plug UPS into itself; this will damage the UPS. • Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground connection. • Do not use extension cords to connect UPS to an AC outlet. • If UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. • The mains socket outlet that supplies the UPS should be installed near the UPS and should be easily accessible. Equipment Connection Warnings • Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. • Do not connect surge suppressors or extension cords to the output of UPS. This might damage the UPS and may affect the surge suppressor and UPS warranties. Battery Warnings • Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS. 2
Features AVRX550U F J H A B C D E G I A ON/OFF/TEST BUTTON • To Turn the UPS ON: Press and hold the ON/OFF/TEST Button for one second.* If utility power is absent, pressing the button will “cold- start” the UPS, i.e. turn it on and supply power from its batteries.** • To Turn the UPS OFF: Press and hold the ON/OFF/TEST switch for one second.* The UPS will be turned completely off (deactivated). • To Run a Self-Test: With your UPS plugged in and turned ON, press and hold the ON/OFF/TEST button for three seconds. CAUTION! To perform a self-test, you must hold the ON/OFF/TEST button continuously for three seconds. If you release the button too early, you will turn the UPS system OFF and cut power to connected equipment loads. To ensure you hold the button for the correct length of time, do not release the button until you hear the UPS System’s audible alarm beep twice. The first beep occurs after one second and indicates that the UPS will turn OFF if the button is released. The second beep occurs after three seconds and indicates that the UPS will perform a self-test if the button is released. The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and charge. All LEDs will be lit and the UPS alarm will sound. See LED descriptions below to determine the results of the self-test. Note: You can leave connected equipment on during a self-test. CAUTION! Do not unplug your UPS to test its batteries. This will remove safe electrical grounding and may introduce a damaging surge into your network connections. *The alarm will beep once briefly after one second has passed. **If fully charged. B “ON/OFF” LED This green LED lights continuously to indicate that the UPS is ON and supplying your equipment with AC power either from a utility source or from the UPS’s internal batteries. If the UPS’s alarm is sounding (4 short beeps followed by a pause), the UPS is operating from its internal batteries. C “OVERLOAD/CHECK BATTERY” LED This red LED lights continuously after a self-test to indicate the capacity of the outlets has been exceeded. To clear the overload, unplug some of your equipment from the outlets; then use the ON/OFF/TEST button to run a self-test. If the UPS continues to detect an overload, remove more equipment and repeat the self-test until successful. CAUTION! Any overload that is not corrected by the user immediately following a self-test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout. The LED flashes to indicate the battery needs to be recharged or replaced. If the LED flashes (and a continuous alarm sounds) during a prolonged blackout or brownout, the UPS’s batteries are nearly out of power; you should save files and shut down your equipment immediately. If the LED flashes following a UPS self-test (after the UPS is turned ON), it may indicate that the battery needs to be replaced. Allow the UPS to recharge continuously for 12 hours; then use the ON/OFF/TEST button to run a self test. If the LED continues to flash, contact Tripp Lite for service. Should your UPS require battery replacement, visit Tripp Lite on the Web at www.tripplite.com to locate the specific replacement battery for your UPS. D AUTOMATIC VOLTAGE REGULATION (internal) Automatically adjusts fluctuations to incoming voltage (under/over voltages) to supply connected equipment with 230V computer-grade output power. Automatic voltage regulation functions separately from battery power (will not drain battery). E BATTERY, SURGE AND NOISE PROTECTED OUTLETS Provide both battery backup and surge protection. Plug your computer, monitor and other critical equipment into these outlets. NOTE: DO NOT PLUG LASER PRINTERS INTO THESE OUTLETS. 3