WArrAntY register on-line today for a chance to win a FrEE tripp Lite rEgIstrAtIOn Owner’s Manual product! www.tripplite.com/warranty PowerVerter ® DC-to-AC Inverter/Chargers 1111 W. 35th Street, Chicago, IL 60609 USA APsX Models Input Output APs Models Input Output Customer Support: 773.869.1234 Invert: 12 VDC 230V, 50 Hz. AC Invert: 12 VDC 120V, 60 Hz. AC www.tripplite.com Charge: 230V, 50 Hz. AC 12 VDC Charge: 120V, 60 Hz. AC 12 VDC Quiet Mobile Power Congratulations! You've purchased the most advanced, feature-rich Inverter/Charger designed as an alternative energy source for residential, commercial or recreational vehicle applications. Tripp Lite Inverter/Chargers are the quiet alternative to gas generators—with no fumes, fuel or noise to deal with! You get AC electricity anywhere and anytime you need it: utility power disruptions, rolling down the highway, dry camping in majestic back country or parked overnight at a money-saving non-electric site. Inverter/Chargers provide your equipment with utility- or generator-supplied AC electricity (filtered through premium ISOBAR® surge protection) whenever available. In addition, your Inverter/Charger automatically recharges your connected battery bank. Whenever blackouts, brownouts or high voltages occur, your Inverter/Charger immedi- ately and automatically switches to battery power. Better for Your Equipment Premium Protection Levels • Built-In ISOBAR Surge Protection ® • Automatic Overload Protection Ideal Output for All Loads • Frequency-Controlled Output • Automatic Load Switching • Balanced Load Sharing Better for Your Batteries Faster Battery Recharge • High-Amp, 3-Stage Battery Charger Critical Battery Protection • High-Efficiency DC-to-AC Inversion Better for You Quiet, Simple, Maintenance-Free Operation • Multi-Function Lights & Switches • Moisture-Resistant Construction* Contents Safety 2 AC Input/Output Connection 10 Feature Identification 3 Service/Maintenance 10 Operation 4-5 Troubleshooting 11 Configuration 5-6 Warranty 11 Battery Selection 7 Espanol 12 Mounting 8 Francais 23 Battery Connection 9 Pynneee 34 * Inverter/Chargers are moisture-resistant, not waterproof. Copyright © 2008. All rights reserved. PowerVerter is a registered trademark of Tripp Lite. ®
Important safety Instructions sAVE tHEsE InstrUCtIOns! This manual contains important instructions and warnings that should be followed during the installation, operation and storage of this product. Location Warnings • Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might accumulate. Mounting should be in the driest location available. • Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit. • Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption. • Do not install near flammable materials, fuel or chemicals. • Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit's internal cooling, eventually causing product damage not covered under warranty. Battery Connection Warnings • The battery should be connected before operating the Inverter/Charger • Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type. • Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some ventilation to outside air. • Sparks may result during final battery connection. Always observe proper polarity as batteries are connected. • Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury or property damage could result. Equipment Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the fail- ure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equip- ment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. • You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of the Inverter/Charger. • Corded Models: Do not modify the Inverter/Charger’s plug or receptacle in a way that eliminates its ground connection. Do not use power adapters that will eliminate the plug’s ground connection. • Connect your Inverter/Charger only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this will damage the device and void your warranty. • The main grounding lug should be connected to earth ground or to the vehicle chassis with a minimum 8 AWG wire. Operation Warnings • Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user-serviceable parts inside. • Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any service work, the battery supply and AC input connection (if any) should therefore be disconnected. • Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode Switch should be in the DC OFF position. Dangerous arcing may result. Caution: These models have a failsafe AC pass-through feature where the AC output will be live (if AC input is available) even though the operating mode switch is set to “DC OFF.” 2
Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use. 1 Configuration DIP Switches: optimize Inverter/Charger 6 AC Output Receptacles operation depending on your application. See Configuration AC Input Receptacle (230V Models): attach input cord to con- section for setting instructions. 7A nect the Inverter/Charger to any source of utility- or generator- 2 Operating Mode Switch: controls Inverter/Charger operation. supplied AC power. The user must provide an appropriate The "AUTO/REMOTE" setting ensures your equipment receives country-specific input cable for 230V Models. See AC Input/ constant, uninterrupted AC power. It also enables the Inverter/ Output Connection section for instructions. Charger to be remotely monitored and controlled with an AC Input Cord (120V Models): plug the Inverter/Charger into optional remote module (Tripp Lite model APSRM4, sold sepa- 7B a utility- or generator-supplied AC power outlet. rately). The "CHARGE ONLY" setting allows your batteries to return to full charge faster by turning the inverter off which halts 8 Resettable Circuit Breakers: protect your Inverter/Charger against battery discharging. The "DC OFF" setting de-energizes the unit damage due to overload or charger failure. See Operation sec- and connects AC OUT to AC IN. See Operation section for set- tion for resetting instructions. ting instructions. 9 Remote Control Module Connector: allows remote monitoring 3 "LINE", "INVERT", "LOAD" LEDs: show whether the and control with an optional module (Tripp Lite model APSRM4, Inverter/Charger is operating from AC line power or DC battery sold separately). See remote module owner’s manual for con- power. It also warns you if the connected equipment load is too nection instructions. high. See Operation section for instructions on reading the indi- 10 Main Ground Lug: properly grounds the Inverter/Charger to cator lights. vehicle grounding system or to earth ground. See Configuration 4 "BATT VOLTAGE" LEDs: these three lights will turn ON in section for instructions. several sequences to show approximate battery level. See Operation 11 Cooling Fan: quiet, efficient fan prolongs equipment service life. section for instructions on reading the indicator lights. 5 DC Power Terminals: connect to your battery terminals. See Battery Connection section for instructions. 1 4 9 3 2 1 4 9 3 2 8 8 11 11 6 6 10 5 5 7A 7B 10 Front View (230V Non-Corded Models) Front View (120V Corded Models) 3