На сайте 124213 инструкций общим размером 502.86 Гб , которые состоят из 6279321 страницы
Руководство пользователя TRIPP LITE APSX6048VRNET. Основные функции, характеристики и условия эксплуатации изложены на 48 страницах документа в pdf формате.
Доступно к просмотру 48 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
Owner’s Manual PowerVerter ® APSX Pure Sine Wave DC-to-AC Inverter/Charger 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support 24V DC Models 48V DC Models Input Output Input Output Invert: 24V DC 230V, 50/60 Hz. AC Invert: 48V DC 208/230V, 50/60 Hz. AC Charge: 230V, 50/60 Hz. AC 24V DC Charge: 208/230V, 50/60 Hz. AC 48V DC Reliable Emergency Backup Power Congratulations! You’ve purchased the most advanced, feature-rich Inverter/Charger designed as an alternative energy source during utility power failures. Tripp Lite APS Inverter/Chargers keep your equipment constantly up and productive through all utility power problems (blackouts, brownouts and high voltages) by automatically inverting DC power from user-supplied batteries into AC power. Built-in surge suppression provides an additional level of equipment protection. When utility power is present, APS Inverter/Chargers automatically pass through power to your equipment while simultaneously recharging your connected battery bank. APS Inverter/Chargers are the quiet alternative to gas generators during emergency backup applications—with no fumes, fuel or noise to deal with! You get AC electricity anywhere and anytime you need it. Better for Your Equipment Premium Protection Levels • Built-In Isobar Surge Protection ® • Automatic Overload Protection Ideal Output for All Loads (including computers) • Pure Sine Wave Output for Maximum Compatibility and Performance • Frequency-Controlled Output • Fast Load Switching • Balanced Load Sharing Better for Your Batteries Faster Battery Recharge • High-Amp, 3-Stage Battery Charger (adjustable) Critical Battery Protection • Battery Charge Conserver (Load Sense) • High-Efficiency DC-to-AC Inversion Better for You Simple, Maintenance-Free Operation • Multi-Function Lights & Switches • Moisture-Resistant Construction* Contents Safety 2 AC Generator Input 10 Feature Identification 3 Service/Maintenance 11 Operation 4 Troubleshooting 11 Configuration 5 Warranty 12 Battery Selection 8 Espanol 13 Battery Connection 9 Francais 25 AC Input/Output Connection 10 ??????? 37 * Inverter/Chargers are moisture-resistant, not waterproof. Copyright © 2012 Tripp Lite. All rights reserved. PowerVerter® and Isobar® are registered trademarks of Tripp Lite. 1 201201049-93-3162.indb 1 1/13/2012 11:34:28 AM
Important Safety Instructions SAVE THESE INSTRUCTIONS! This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Inverter/Chargers. Location Warnings • Install your Inverter/Charger in a location or compartment that minimizes exposure to heat, dust, direct sunlight and moisture. • Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might accumulate. Mounting should be in the driest location available. • Leave a minimum of 50 mm clearance at front and back of the Inverter/Charger for proper ventilation. The heavier the load of connected equipment, the more heat will be generated by the unit. • Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption. • Do not install near flammable materials, fuel or chemicals. • Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered under warranty. • Mount your Inverter/Charger BEFORE DC battery and AC power connection. Failure to follow these instructions may lead to personal injury and/or damage to the Inverter/Charger and connected systems. Battery Connection Warnings • The battery should be connected before operating the Inverter/Charger. • Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type. • Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be installed in a “dead air” compartment. Ideally, any compartment would have some ventilation to outside air. • Sparks may result during final battery connection. Always observe proper polarity as batteries are connected. • Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury or property damage could result. Equipment Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. • Connect your Inverter/Charger only to a properly grounded AC power source. Do not connect the unit to itself; this will damage the device and void your warranty. • The main grounding lug should be connected to earth ground with a minimum 3.15 mm diameter (8AWG) wire. Operation Warnings • Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside. • Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any service work, the battery supply and AC input connection should therefore be disconnected. • Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode Switch should be in the OFF position. Dangerous arcing may result. 2 201201049-93-3162.indb 2 1/13/2012 11:34:28 AM
Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use. 1 Configuration DIP Switches: optimize Inverter/Charger 8 Remote Control Module Connector: allows remote operation depending on your application. See Configuration monitoring and control with an optional module (Tripp Lite section for setting instructions. model APSRM4, sold separately). See remote module owner’s manual for connection instructions. 2 Operating Mode Rocker Switch: controls Inverter/Charger operation. The “AUTO/REMOTE” setting ensures your equipment 9 Battery Charge Conserver (Load Sense) Control: receives constant, uninterrupted AC power. It also enables the conserves battery power by setting the low-load level at which Inverter/Charger to be remotely monitored and controlled with the Inverter/Charger’s inverter automatically shuts off. See an optional remote module (Tripp Lite model APSRM4, sold Configuration section for setting instructions. separately). The “CHARGE ONLY” setting allows your batteries to return to full charge faster by turning the inverter off, which 10 Main Ground Lug: properly grounds the Inverter/Charger to halts battery discharging. The “OFF” position de-energizes the earth ground. See Battery Connection section for connection unit (including its AC output). See Operation section for setting instructions. instructions. 11 Thermostatically-Controlled Cooling Fans: quiet, efficient 3 Operation Indicator Lights: intuitive “traffic light” signals fans regulate internal temperature and prolong equipment show whether the Inverter/Charger is operating from AC line service life. Fans run at variable speed, depending on power or DC battery power. It also warns you if the connected temperature and load. equipment load is too high. See Operation section for 12 Remote Generator Start Connector: automatically cycles instructions on reading indicator lights. generator based on battery voltage. Use with user-supplied 4 Battery Indicator Lights: intuitive “traffic light” signals show cable. See Configuration section for more information. approximate charge level of your battery. See Operation section 13 Remote Battery Temperature Sensing Connector: prolongs for instructions on reading indicator lights. battery life by adjusting charge based on battery temperature. 5 DC Power Terminals: connect to your battery terminals. See Contact Tripp Lite for optional temperature sensing cable Battery Connection section for connection instructions. accessory. See Configuration section for more information. 6 Hardwire AC Input/Output Terminal Strip (Access Panel): 14 RS-232 Serial Communication Connector: can be used to securely connects the Inverter/Charger to facility electrical attach an external SNMP/Web management module (Tripp Lite system. See Input/Output Connection section for connection model SNMPWEBSOLOHV) to remotely monitor and control instructions. your inverter/charger. 7 Knockouts for AC Input/Output Conduits 15 12V DC Power Connector: independently powers SNMP/Web management module (Tripp Lite model SNMPWEBSOLOHV) without the use of an AC outlet. 13 12 1 4 8 3 9 5 2 14 15 6 On Side, Not Shown. 7 11 10 3 201201049-93-3162.indb 3 1/13/2012 11:34:28 AM