На сайте 124107 инструкций общим размером 502.41 Гб , которые состоят из 6273535 страниц
Руководство пользователя PHILIPS Sonicare HX 6511. Основные функции, характеристики и условия эксплуатации изложены на 9 страницах документа в pdf формате.
Доступно к просмотру 9 страниц. Рекомендуем вам скачать файл инструкции, поскольку онлайн просмотр документа может сильно отличаться от оригинала.
1 2 3 la brosse a dents sonic HydroClean A 4 5 1 EasyClean 2 500 series Rechargeable B sonic toothbrush C 3 4 D 6 7 E 8 9 10 11 12 13 14
EnglISh user manual, the appliance is safe to use based on start feature and for areas where excess staining scientific evidence available today. occurs, an additional 30 seconds of brushing time can Introduction General description (Fig. 1) be spent to assist with stain removal. Congratulations on your purchase and welcome to A Replaceable Sonicare brush head Features Philips! To fully benefit from the support that Philips B Battery charge indicator (specific types only) Easy-start offers, register your product at www.philips.com/ C Power on/off button welcome. This Sonicare model comes with the Easy-start D Handle feature activated. Important E Charger The Easy-start feature gently increases the power Read this user manual carefully before you use the Preparing for use over the first 14 brushings. appliance and save it for future reference. Attaching the brush head Note: Each of the first 14 brushings must be at least Danger 1 minute in length to advance through the Easy-start - Keep the charger away from water. 1 Align the front of the brush head with the ramp-up cycle properly. - Do not place or store the appliance where it front of the toothbrush handle. Deactivating and activating the Easy- can fall or be pulled in a bathtub, washbasin, 2 Push the brush head onto the metal start feature sink etc. - Do not immerse the charger in water or any shaft (Fig. 2). 1 Attach the brush head to the handle. other liquid. Note: There is a small gap between the brush head - After cleaning, make sure the charger is and the handle. 2 Place the handle in the plugged-in charger. To deactivate Easy-start: - completely dry before you connect it to the Charging the appliance Press and hold the power on/off button for 2 mains. seconds. You hear 1 beep to indicate that the Easy- Warning 1 Put the plug of the charger in the wall socket. start feature has been deactivated. - The mains cord cannot be replaced. If the 2 Place the handle on the charger. - To activate Easy-start: mains cord is damaged, discard the charger. - The battery charge indicator shows the Press and hold the power on/off button for 2 Always have the charger replaced with one of approximate remaining battery charge (Fig. 3). seconds. You hear 2 beeps to indicate that the the original type in order to avoid a hazard. Easy-start feature has been activated. - If the appliance is damaged in any way (brush - - Solid green light: 91-100% Note: Using the Easy-start feature beyond the initial Flashing green light: 0-90% head, toothbrush handle and/or charger), stop - Flashing green light and 3 beeps after the ramp-up period is not recommended and reduces using it. - This appliance contains no serviceable parts. brushing cycle: less than 5% and toothbrush has Sonicare’s effectiveness in removing plaque. to be recharged. If the appliance is damaged, contact the Smartimer Consumer Care Centre in your country (see Note: To keep the battery fully charged at all times, After 2 minutes, the Smartimer automatically chapter ‘Guarantee and service’). you may keep your Sonicare on the charger when not - Do not use the charger outdoors or near in use. It takes at least 24 hours to fully charge the switches off the toothbrush. To pause or stop brushing during the 2-minute heated surfaces. battery. - This appliance is not intended for use by cycle, press the on/off button. If you press the on/ off button again within 30 seconds, the Smartimer persons (including children) with reduced Using the appliance picks up where you left off. physical, sensory or mental capabilities, or lack 1 Wet the bristles and apply a small amount of of experience and knowledge, unless they toothpaste. Quadpacer have been given supervision or instruction 2 Place the toothbrush bristles against the teeth The Quadpacer is an interval timer. At 30, 60 and concerning use of the appliance by a person at a slight angle towards the gumline (Fig. 4). 90 seconds, you hear a short beep and pause in responsible for their safety. - Children should be supervised to ensure that 3 Press the power on/off button to switch on the brushing action. This is your signal to move to the next section of your mouth. they do not play with the appliance. the Sonicare. Caution 4 Apply light pressure to maximise Sonicare’s Cleaning - If you have had oral or gum surgery in the effectiveness and let the Sonicare toothbrush Do not place brush head, the handle and the previous 2 months, consult your dentist before do the brushing for you. Do not scrub. charger in the dishwasher. you use the toothbrush. - Consult your dentist if excessive bleeding 5 Gently move the brush head slowly across 1 Rinse the brush head and bristles after each the teeth in a small back and forth motion use. Let the brush head air-dry only (Fig. 7). occurs after using this toothbrush or if bleeding so the longer bristles reach between your continues to occur after 1 week of use. 2 Remove the brush head once a week and - If you have medical concerns, consult your teeth. Continue this motion throughout the clean the connection between the brush head brushing cycle. doctor before you use the Sonicare. and the handle (Fig. 8). - The Sonicare toothbrush complies with Note: To make sure you brush evenly throughout the Do not use sharp objects to press on the rubber the safety standards for electromagnetic mouth, divide your mouth into 4 sections using the seal, as this may cause damage. devices. If you have a pacemaker or other Quadpacer feature (see chapter ‘Features’). implanted device, contact your physician or 6 Brush each section for 30 seconds for a total 3 Clean the rest of the handle periodically with the manufacturer of the implanted device prior brushing time of 2 minutes. Start with section mild soap and a moist cloth (Fig. 9). to use. - This appliance has only been designed for 1 (outside top teeth) and then brush section 4 Unplug the charger before you clean it. Use a 2 (inside top teeth). Continue with section damp cloth to wipe the surface of the charger. cleaning teeth, gums and tongue. Do not use it 3 (outside bottom teeth) and finally brush for any other purpose. Stop using the appliance section 4 (inside bottom teeth). (Fig. 5) Replacement and contact your doctor if you experience any Brush head discomfort or pain. 7 After you have completed the 2-minute - Do not use other brush heads than the ones brushing cycle, you can spend additional Replace Sonicare brush heads every 3 months for recommended by the manufacturer. time brushing the chewing surfaces of your optimal results. - If your toothpaste contains peroxide, baking teeth and areas where staining occurs. soda or other bicarbonate (common in You may also brush your tongue, with the Environment whitening toothpastes), thoroughly clean the toothbrush switched on or off, as you - Do not throw away the appliance with the brush head and the handle with soap and prefer (Fig. 6). normal household waste at the end of its life, water after each use. Otherwise the plastic may but hand it in at an official collection point for crack. The Sonicare is safe to use on: recycling. By doing this, you help to preserve - Braces (brush heads wear out sooner when the environment (Fig. 10). Electromagnetic fields (EMF) used on braces) - The built-in rechargeable battery contains This Philips appliance complies with all standards - Dental restorations (fillings, crowns, veneers) substances that may pollute the environment. regarding electromagnetic fields (EMF). If handled Note: When the Sonicare is used in clinical studies, the Always remove the battery before you properly and according to the instructions in this discard and hand in the appliance at an official handle should be fully charged. Deactivate the Easy- 2 4235.020.4541.1
collection point. Dispose of the battery at an official collection point for batteries. If you have trouble removing the battery, you can also take the appliance to a Philips service centre. The staff of this centre will remove the battery for you and will dispose of it in an environmentally safe way (Fig. 11). Removing the rechargeable battery Please note that this process is not reversible. To remove the rechargeable battery, you need a flat-head (standard) screwdriver. Observe basic safety precautions when you follow the procedure outlined below. Be sure to protect your eyes, hands, fingers, and the surface on which you work. 1 To deplete the rechargeable battery of any charge, remove the handle from the charger, switch on the Sonicare and let it run until it stops. Repeat this step until you can no longer switch on the Sonicare. 2 Insert a screwdriver into the slot in the bottom of the handle and turn counterclockwise to release the bottom cap (Fig. 12). 3 Hold the handle upside down and push down on the shaft to release the internal components of the handle (Fig. 13). 4 Insert the screwdriver under the circuit board, next to the battery connections, and twist to break the connections. Remove the circuit board and pry the battery from the plastic carrier (Fig. 14). guarantee and service If you need service or information or if you have a problem, please visit the Philips website at www.philips.com or contact the Philips Consumer Care Centre in your country (you find its phone number in the worldwide guarantee leaflet). If there is no Consumer Care Centre in your country, go to your local Philips dealer. guarantee restrictions The terms of the international guarantee do not cover the following: - Brush heads - Damage caused by misuse, abuse, neglect, alterations or unauthorised repair - Normal wear and tear, including chips, scratches, abrasions, discolouration or fading 3 4235.020.4541.1